Left ventricular function in atrial fibrillation during overdrive pacing.

Viren Vankawala1, Bashar Markabawi, Sara Dainiak, Morgan Werner, W David Hager, William Farrel, Arnold M Katz, David I Silverman.   

Abstract

OBJECTIVE: Our purpose was to measure the effect of ventricular pacing in patients with atrial fibrillation (AF) on stroke volume and cardiac output.
BACKGROUND: Unceasing variation in cycle length in AF decreases stroke volume and cardiac output. Because ventricular-inhibited pacing after atrioventricular node ablation has been reported to improve left ventricular performance, we tested the hypothesis that overdrive pacing would produce a similar benefit by regularizing cycle length. METHODS AND
RESULTS: We studied 18 patients with chronic AF and permanent pacemakers. The aortic time velocity integral (TVI) was measured with continuous-wave Doppler and was used as a surrogate measure of stroke volume (stroke volume = TVI x aortic valve area, and aortic valve area is constant whether in AF or during pacing). For each patient, the linear relation between preceding cycle length and TVI in AF was used to estimate relative stroke volume (TVI compared within each patient) at a preceding cycle length of 666 ms in AF, and a similar comparison between AF and pacing was made at the minimum allowable pacing rate. Relative stroke volume in AF was then compared with relative stroke volume at both the fixed cycle (666 ms) and the minimum allowable rate. During pacing at 666 ms, relative stroke volume increased significantly by 18% (t = 2.8, P =.048), but there was no difference in cardiac output during pacing at the minimum possible rate and the corresponding preceding cycle length in AF.
CONCLUSION: Our data suggest that regularization of ventricular rhythm by overdrive pacing in patients with AF only improves stroke volume (and by extension, cardiac output) at pacing rates at the outer limit of and above the normal physiologic range.

Entities:  

Mesh:

Year:  2002        PMID: 12040344     DOI: 10.1067/mhj.2002.121272

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  3 in total

1.  Overdrive pacing for endovascular repair of an aortic arch aneurysm.

Authors:  Sherif S Zaky; Theodore Marks
Journal:  J Anesth       Date:  2009-11-18       Impact factor: 2.078

2.  Adverse effects of continuous ventricular pacing in patients with slower atrial fibrillation and normal left ventricular systolic function.

Authors:  John A Chiladakis; Nikolaos Koutsogiannis; Andreas Kalogeropoulos; Panagiotis Arvanitis; Dimitrios Alexopoulos
Journal:  Ann Noninvasive Electrocardiol       Date:  2008-04       Impact factor: 1.468

3.  Usefulness of rate regulation through continuous ventricular pacing in patients with drug-controlled slower atrial fibrillation and normal or depressed left ventricular systolic function.

Authors:  John Chiladakis; Nikolaos Koutsogiannis; Andreas Kalogeropoulos; Fani Zagli; Panagiotis Arvanitis; Dimitrios Alexopoulos
Journal:  Heart Vessels       Date:  2008-11-27       Impact factor: 2.037

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.