Electrophysiologically guided amiodarone therapy versus the implantable cardioverter-defibrillator for sustained ventricular tachyarrhythmias after myocardial infarction: results of long-term follow-up.

Jürg Schläpfer1, Fabrice Rapp, Lukas Kappenberger, Martin Fromer.   

Abstract

OBJECTIVES: We sought to compare the long-term survival rates of patients with sustained ventricular tachyarrhythmia after myocardial infarction (MI) who were treated according to the results of electrophysiological (EP) study either with amiodarone or an implantable cardioverter-defibrillator (ICD).
BACKGROUND: Patients with sustained ventricular tachyarrhythmias after MI are at high risk of sudden cardiac death (SCD). However, data comparing the long-term survival rates of patients treated with amiodarone or ICD, according to the results of EP testing, are lacking.
METHODS: Patients underwent a first EP study at baseline and a second one after a loading dose of amiodarone of 14 +/- 2.9 g. According to the results of the second EP study, patients were classified either as responders or non-responders to amiodarone; non-responders were eventually treated with an ICD.
RESULTS: Eighty-four consecutive patients with MI (78 men; 21-77 years old; mean left ventricular (LV) ejection fraction 36 +/- 11%) were consecutively included. Forty-three patients (51%) were responders, and 41 patients (49%) were non-responders to amiodarone therapy. During a mean follow-up period of 63 +/- 30 months, SCD and total mortality rates were significantly higher in the amiodarone-treated patients (p = 0.03 and 0.02, respectively).
CONCLUSIONS: The long-term survival of patients with sustained ventricular tachyarrhythmias after MI, with depressed LV function, is significantly better with an ICD than with amiodarone therapy, even when stratified according to the results of the EP study. These patients should benefit from early ICD placement, and any previous amiodarone treatment seems to have no additional value.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12039497     DOI: 10.1016/s0735-1097(02)01863-6

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  3 in total

Review 1.  Relevance of guideline-based ICD indications to clinical practice.

Authors:  Nora Al-Jefairi; Haran Burri
Journal:  Indian Heart J       Date:  2013-12-22

Review 2.  A Comparative Study Between Amiodarone and Implantable Cardioverter-Defibrillator in Decreasing Mortality From Sudden Cardiac Death in High-Risk Patients: A Systematic Review and Meta-Analysis.

Authors:  Hany A Zaki; Eman Shaban; Khalid Bashir; Haris Iftikhar; Adel Zahran; Waleed Salem; Amr Elmoheen
Journal:  Cureus       Date:  2022-06-16

3.  Health care policy and regulatory implications on medical device innovations: a cardiac rhythm medical device industry perspective.

Authors:  Arjun Sharma; Anthony Blank; Parashar Patel; Kenneth Stein
Journal:  J Interv Card Electrophysiol       Date:  2013-03-10       Impact factor: 1.900