Literature DB >> 12038772

Determination of oceanic carbon dioxide using a carbonate-selective electrode.

Yong Suk Choi1, Larisa Lvova, Jae Ho Shin, Seong Hee Oh, Chang Suk Lee, Byeong Hyo Kim, Geun Sig Cha, Hakhyun Nam.   

Abstract

Potentiometric properties of the PVC membrane-based electrodes prepared with molecular tweezer-type neutral carriers, 3,12-bis(TFAB)CA and deoxy-3,12-bis(TFAB)CA, and trifluoroacetyl-p-decylbenzene (TFADB) were measured in buffered electrolytes (0.1 M Tris-H2SO4, pH 8.6 and 8.0) and artificial seawater. It was observed that the deoxy-3,12-bis(TFAB)CA-based electrode provides greatly enhanced carbonate selectivity over chloride (log K(CO3(2-), Cl-)POT approximately -6) and other minor anions present in seawater. Thus, we explored the possibility of applying this new carbonate-selective electrode for direct determination of oceanic carbon dioxide. The total carbon dioxide (TCO2) level in surface Yellow Sea water was determined with the deoxy-3,12-bis(TFAB)CA-based electrode, Severinghaus-type CO2 gas sensor, and the traditional potentiometric titration methods. The results showed that the carbonate-selective electrode provides accurate oceanic TCO2 determination comparable to that obtainable with the other two methods. The analytical procedure based on a carbonate-selective electrode is clearly advantageous over other conventional methods: it does not require any sample pretreatment and extra reagents other than the standard calibration solutions, while providing the measured results directly and immediately.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12038772     DOI: 10.1021/ac0108459

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  Dynamic changes in carbonate chemistry in the microenvironment around single marine phytoplankton cells.

Authors:  Abdul Chrachri; Brian M Hopkinson; Kevin Flynn; Colin Brownlee; Glen L Wheeler
Journal:  Nat Commun       Date:  2018-01-08       Impact factor: 14.919

2.  Lansoprazole-Based Colorimetric Chemosensor for Efficient Binding and Sensing of Carbonate Ion: Spectroscopy and DFT Studies.

Authors:  Mahdieh Darroudi; Ghodsi Mohammadi Ziarani; Shahriyar Bahar; Jahan B Ghasemi; Alireza Badiei
Journal:  Front Chem       Date:  2021-02-02       Impact factor: 5.221

3.  Influence of Experimental Conditions on Electronic Tongue Results-Case of Valsartan Minitablets Dissolution.

Authors:  Małgorzata Wesoły; Anna Kluk; Małgorzata Sznitowska; Patrycja Ciosek; Wojciech Wróblewski
Journal:  Sensors (Basel)       Date:  2016-08-23       Impact factor: 3.576

4.  Fluorescein Based Three-channel Probe for the Selective and Sensitive Detection of CO32- Ions in an Aqueous Environment and Real Water Samples.

Authors:  Erman Karakuş; Eda Erdemir; Garen Suna; Lokman Liv; Simay Gunduz; Şevval Arzu Can
Journal:  J Fluoresc       Date:  2021-08-06       Impact factor: 2.217

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.