Literature DB >> 12038759

Surface-alkylated polystyrene monolithic columns for peptide analysis in capillary liquid chromatography-electrospray ionization mass spectrometry.

Xian Huang1, Sheng Zhang, Gary A Schultz, Jack Henion.   

Abstract

Macroporous poly(styrene-divinylbenzene) (PS-DVB) monoliths were prepared by in situ polymerization in PEEK, fused silica, or stainless steel tubing having an inner diameter of 75 or 125 microm. A process is described for subsequent alkylation of the flow-contacting surfaces of the monoliths. The process treats all the surfaces including through-pore surfaces of the rigid macroporous monolith with a solution containing a dissolved Friedel-Crafts catalyst, an alkyl halide (1-chlorooctadecane), and an organic solvent. This process produces an improved reversed-phase liquid chromatographic separation of peptides compared to an unmodified monolithic PS-DVB column. The surface octadecylation is not necessary for a reversed-phase separation of proteins since both unmodified and modified columns provide comparable results. Tryptic protein digests, standard proteins, and standard peptides were used to evaluate the monolithic columns by employing electrospray mass spectrometry detection. Potential applications in proteomics studies by mass spectrometry, which use the alkylated monolithic column engaged onto the nanofabricated electrospray ionization chip, are also discussed.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12038759     DOI: 10.1021/ac011202w

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  2 in total

1.  Stability and repeatability of capillary columns based on porous monoliths of poly(butyl methacrylate-co-ethylene dimethacrylate).

Authors:  Laurent Geiser; Sebastiaan Eeltink; Frantisek Svec; Jean M J Fréchet
Journal:  J Chromatogr A       Date:  2006-12-19       Impact factor: 4.759

Review 2.  CEC: selected developments that caught my eye since the year 2000.

Authors:  Frantisek Svec
Journal:  Electrophoresis       Date:  2009-06       Impact factor: 3.535

  2 in total