Viscoelastic protection from endothelial damage by air bubbles.

Eung Kweon Kim1, Stephen M Cristol, Shin J Kang, Henry F Edelhauser, Hyung Lae Kim, Jae Bum Lee.   

Abstract

PURPOSE: To determine whether viscoelastic materials effectively protect the corneal endothelium from air bubbles.
SETTING: Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea.
METHODS: Human eye-bank and rabbit eyes had a standardized phacoemulsification procedure with or without viscoelastic material (Healon [sodium hyaluronate 1.0%], Healon GV [sodium hyaluronate 1.4%], or Viscoat [chondroitin sulfate 4.0%-sodium hyaluronate 3.0%]). The integrity of the endothelium was examined after the procedure with F-actin staining and scanning electron microscopy. Rabbit eyes with and without viscoelastic material (Healon or Viscoat) had a standardized irrigation/aspiration (I/A) procedure. The mucinous layer of the endothelium was examined after the procedure with transmission electron microscopy.
RESULTS: In the phacoemulsification experiment without viscoelastic material, with Healon, and with Healon GV, the endothelium of human and rabbit corneas had many areas of cell loss in a pattern consistent with air-bubble damage. With Viscoat, endothelial cells remained intact. In the I/A experiment, the mucinous layer of Viscoat-exposed rabbit endothelium appeared thinner. In the same experiments without viscoelastic material or with Healon, the mucinous layer of the endothelium appeared normal.
CONCLUSIONS: Viscoat effectively protected the endothelium from air-bubble damage. Viscoat appears to protect the endothelium by acting as a physical barrier. Its adherence is probably related to the way it interacts with the mucinous layer of the endothelium.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12036653     DOI: 10.1016/s0886-3350(01)01319-0

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  4 in total

1.  Three cases of Descemet's membrane detachment after cataract surgery.

Authors:  In Sik Kim; Jung Chul Shin; Chan Yeong Im; Eung Kweon Kim
Journal:  Yonsei Med J       Date:  2005-10-31       Impact factor: 2.759

2.  Corneal endothelial morphology and function after torsional and longitudinal ultrasound mode phacoemulsification.

Authors:  László Jr Módis; Eszter Szalai; Zsuzsa Flaskó; Gábor Németh
Journal:  Rom J Ophthalmol       Date:  2016 Apr-Jun

3.  Early changes in corneal edema following torsional phacoemulsification using anterior segment optical coherence tomography and Scheimpflug photography.

Authors:  Ying-Jun Li; Hyo-Jin Kim; Choun-Ki Joo
Journal:  Jpn J Ophthalmol       Date:  2011-05-11       Impact factor: 2.447

4.  Evaluation of the safety of anterior capsule staining with trypan blue under air: a retrospective analysis.

Authors:  Young Min Park; Jong Soo Lee; Ji Eun Lee; Yeon Ji Jo; Ik Soo Byon; Sung Who Park
Journal:  Int J Ophthalmol       Date:  2022-03-18       Impact factor: 1.779

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.