Literature DB >> 12034953

Temporal subtraction for detection of solitary pulmonary nodules on chest radiographs: evaluation of a commercially available computer-aided diagnosis system.

Takeshi Johkoh1, Takenori Kozuka, Noriyuki Tomiyama, Seiki Hamada, Osamu Honda, Naoki Mihara, Mitsuhiro Koyama, Mitsuko Tsubamoto, Munehiro Maeda, Hironobu Nakamura, Hironori Saki, Keiichi Fujiwara.   

Abstract

PURPOSE: To evaluate the usefulness of a commercially available computer-aided diagnosis (CAD) system that incorporates temporal subtraction for the detection of solitary pulmonary nodules on chest radiographs by readers with different levels of experience.
MATERIALS AND METHODS: Sixty pairs of chest radiographs in 30 patients with newly detected solitary pulmonary nodules and 30 normal cases, all confirmed with serial chest computed tomography (CT), were obtained from screen-film or digital radiographic systems and were digitized (spatial resolution, 0.171 mm/pixel). Temporal subtraction images were produced with an iterative image-warping technique. Five chest radiologists and five residents evaluated both image sets for solitary nodules: set A, current and prior radiographs with temporal subtraction images, and set B, current and prior radiographs only. Assessment was performed with receiver operating characteristic (ROC) analysis of the images on a monitor (pixel size, 1,280 x 1,024) equipped with the system. The reading time needed by each reader was recorded in each case.
RESULTS: For the chest radiologists, no statistically significant difference was found between set A (area under the ROC curve [A(z)] = 0.934) and set B (A(z) = 0.964). For the residents, however, observer performance in set A (A(z) = 0.907) was superior to that in set B (A(z) = 0.855) (P <.05). For both groups, the mean reading time per case for set A (chest radiologists, 16.7 seconds; residents, 15.7 seconds) was significantly (P <.05) shorter than that for set B (chest radiologists, 20.4 seconds; residents, 26.2 seconds).
CONCLUSION: For the detection of solitary pulmonary nodules, the CAD system with temporal subtraction can promote efficiency for established chest radiologists and improvement in accuracy for less experienced readers.

Entities:  

Mesh:

Year:  2002        PMID: 12034953     DOI: 10.1148/radiol.2233010957

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  5 in total

1.  Evaluation of the image quality of temporal subtraction images produced automatically in a PACS environment.

Authors:  Shuji Sakai; Hiroyasu Soeda; Akio Furuya; Hidetake Yabuuchi; Takashi Okafuji; Keiji Yamamoto; Hiroshi Honda; Kunio Doi
Journal:  J Digit Imaging       Date:  2006-12       Impact factor: 4.056

2.  Evaluation of usefulness of color digital summation radiography for solitary pulmonary nodules on chest radiographs.

Authors:  Yuji Ogata; Hiroaki Naito; Noriyuki Tomiyama; Seiki Hamada; Mitusko Tsubamoto; Atsuo Inoue; Sachiko Murai; Hiromitu Sumikawa; Takashi Ueguchi; Mitsuhiro Matsumoto; Shinichi Tamura; Hiroyuki Nishinosono; Hironobu Nakamura; Takeshi Johkoh
Journal:  Radiat Med       Date:  2006-06

3.  Integration of temporal subtraction and nodule detection system for digital chest radiographs into picture archiving and communication system (PACS): four-year experience.

Authors:  Shuji Sakai; Hidetake Yabuuchi; Yoshio Matsuo; Takashi Okafuji; Takeshi Kamitani; Hiroshi Honda; Keiji Yamamoto; Keiichi Fujiwara; Naoki Sugiyama; Kunio Doi
Journal:  J Digit Imaging       Date:  2007-03-01       Impact factor: 4.056

4.  [Detection of lung nodules. New opportunities in chest radiography].

Authors:  S Pötter-Lang; S Schalekamp; C Schaefer-Prokop; M Uffmann
Journal:  Radiologe       Date:  2014-05       Impact factor: 0.635

Review 5.  Digital chest radiography: an update on modern technology, dose containment and control of image quality.

Authors:  Cornelia Schaefer-Prokop; Ulrich Neitzel; Henk W Venema; Martin Uffmann; Mathias Prokop
Journal:  Eur Radiol       Date:  2008-04-23       Impact factor: 5.315

  5 in total