Literature DB >> 12033309

Sequencing of argentinated peptides by means of matrix-assisted laser desorption/ionization tandem mass spectrometry.

Ivan K Chu1, David M Cox, Xu Guo, Inga Kireeva, Tai Chu Lau, John C McDermott, K W Michael Siu.   

Abstract

Argentinated peptide ions are formed in abundance under matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) conditions in the presence of Ag+ ions. These argentinated peptide ions are fragmented facilely under MALDI-MS/MS conditions to yield [b(n) + OH + Ag]+, [b(n) - H + Ag]+ and [a(n) - H + Ag]+ ions that are indicative of the C-terminal sequence. These observations parallel those made earlier under electrospray MS conditions (Chu, I. K; Guo, X.; Lau, T.-C.; Siu, K W. M. Anal. Chem. 1999, 71, 2364-2372). A mixed protonated and argentinated tryptic peptide map was generated from 37 fmol of bovine serum albumin (BSA) using MALDI-MS. MALDI-MS/MS data from four argentinated peptides at a protein amount of 350 fmol unambiguously identified the protein as BSA. Sequence-tag analysis of two argentinated tryptic peptides was used to identify unambiguously myocyte enhancer factor 2A, which had been recombinantly expressed in a bacterial cell line.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12033309     DOI: 10.1021/ac0111006

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

1.  MS(n) characterization of protonated cyclic peptides and metal complexes.

Authors:  Sheldon M Williams; Jennifer S Brodbelt
Journal:  J Am Soc Mass Spectrom       Date:  2004-07       Impact factor: 3.109

2.  Attachment of metal trications to peptides.

Authors:  Alexandre A Shvartsburg; Richard C Jones
Journal:  J Am Soc Mass Spectrom       Date:  2004-03       Impact factor: 3.109

3.  Gas-phase ion/ion reactions of multiply protonated polypeptides with metal containing anions.

Authors:  Kelly A Newton; Ravi Amunugama; Scott A McLuckey
Journal:  J Phys Chem A       Date:  2005-04-28       Impact factor: 2.781

4.  A method to enhance a1 ions and application for peptide sequencing and protein identification.

Authors:  Ning Liu; Wan Chan; Kim-Chung Lee; Zongwei Cai
Journal:  J Am Soc Mass Spectrom       Date:  2009-02-21       Impact factor: 3.109

5.  Locating Pb2+ and Zn2+ in zinc finger-like peptides using mass spectrometry.

Authors:  Laura Banu; Voislav Blagojevic; Diethard K Bohme
Journal:  J Am Soc Mass Spectrom       Date:  2013-08-02       Impact factor: 3.109

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.