Quantitative gated SPECT: the effect of reconstruction filter on calculated left ventricular ejection fractions and volumes.

Graham A Wright1, Mark McDade, William Martin, Ian Hutton.   

Abstract

Gated SPECT (GSPECT) offers the possibility of obtaining additional functional information from perfusion studies, including calculation of left ventricular ejection fraction (LVEF). The calculation of LVEF relies upon the identification of the endocardial surface, which will be affected by the spatial resolution and statistical noise in the reconstructed images. The aim of this study was to compare LVEFs and ventricular volumes calculated from GSPECT using six reconstruction filters. GSPECT and radionuclide ventriculography (RNVG) were performed on 40 patients; filtered back projection was used to reconstruct the datasets with each filter. LVEFs and volumes were calculated using the Cedars-Sinai QGS package. The correlation coefficient between RNVG and GSPECT ranged from 0.81 to 0.86 with higher correlations for smoother filters. The narrowest prediction interval was 111 +/- 2%. There was a trend towards higher LVEF values with smoother filters, the ramp filter yielding LVEFs 2.55 +/- 3.10% (p < 0.001) lower than the Hann filter. There was an overall fall in ventricular volumes with smoother filters with a mean difference of 13.98 +/- 10.15 ml (p < 0.001) in EDV between the Butterworth-0.5 and Butterworth-0.3 filters. In conclusion, smoother reconstruction filters lead to lower volumes and higher ejection fractions with the QGS algorithm, with the Butterworth-0.4 filter giving the highest correlation with LVEFs from RNVG. Even if the optimal filter is chosen the uncertainty in the measured ejection fractions is still too great to be clinically acceptable.

Entities:  

Mesh:

Year:  2002        PMID: 12030567     DOI: 10.1088/0031-9155/47/8/402

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Measurement of left ventricular volumes and ejection fraction by quantitative gated SPET, contrast ventriculography and magnetic resonance imaging: a meta-analysis.

Authors:  Chisato Kondo; Kenji Fukushima; Kiyoko Kusakabe
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-04-04       Impact factor: 9.236

2.  Do reconstruction filters really effect the volume and ejection fraction calculation with 99Tc-sestamibigated myocardial SPECT?

Authors:  Ora Manish; Subhash Chand Kheruka; Sukanta Barai; Sanjay Gambhir
Journal:  Indian J Nucl Med       Date:  2010-10

Review 3.  Filters in 2D and 3D Cardiac SPECT Image Processing.

Authors:  Maria Lyra; Agapi Ploussi; Maritina Rouchota; Stella Synefia
Journal:  Cardiol Res Pract       Date:  2014-04-01       Impact factor: 1.866

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.