An analysis of MCNP cross-sections and tally methods for low-energy photon emitters.

John J Demarco1, Robert E Wallace, Kirsten Boedeker.   

Abstract

Monte Carlo calculations are frequently used to analyse a variety of radiological science applications using low-energy (10-1000 keV) photon sources. This study seeks to create a low-energy benchmark for the MCNP Monte Carlo code by simulating the absolute dose rate in water and the air-kerma rate for monoenergetic point sources with energies between 10 keV and 1 MeV. The analysis compares four cross-section datasets as well as the tally method for collision kerma versus absorbed dose. The total photon attenuation coefficient cross-section for low atomic number elements has changed significantly as cross-section data have changed between 1967 and 1989. Differences of up to 10% are observed in the photoelectric cross-section for water at 30 keV between the standard MCNP cross-section dataset (DLC-200) and the most recent XCOM/NIST tabulation. At 30 keV, the absolute dose rate in water at 1.0 cm from the source increases by 7.8% after replacing the DLC-200 photoelectric cross-sections for water with those from the XCOM/NIST tabulation. The differences in the absolute dose rate are analysed when calculated with either the MCNP absorbed dose tally or the collision kerma tally. Significant differences between the collision kerma tally and the absorbed dose tally can occur when using the DLC-200 attenuation coefficients in conjunction with a modern tabulation of mass energy-absorption coefficients.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12030558     DOI: 10.1088/0031-9155/47/8/307

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  10 in total

1.  Ice as a water-equivalent solid medium for brachytherapy dosimetric measurements.

Authors:  Haijun Song; Zhe Chen; Ning Yue; Qingrong Wu; Fang-Fang Yin
Journal:  Radiat Environ Biophys       Date:  2008-12-09       Impact factor: 1.925

2.  Dosimetric characterization of the GammaClip™ 169Yb low dose rate permanent implant brachytherapy source for the treatment of nonsmall cell lung cancer postwedge resection.

Authors:  Blake Currier; John J Munro; David C Medich
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

3.  Photon energy spectrum emitted by a novel polymer-encapsulated 103Pd source and its effect on the dose rate constant.

Authors:  Sabrina Khan; Zhe Jay Chen; Ravinder Nath
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

4.  A dosimetric uncertainty analysis for photon-emitting brachytherapy sources: report of AAPM Task Group No. 138 and GEC-ESTRO.

Authors:  Larry A DeWerd; Geoffrey S Ibbott; Ali S Meigooni; Michael G Mitch; Mark J Rivard; Kurt E Stump; Bruce R Thomadsen; Jack L M Venselaar
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

5.  A novel ytterbium-169 brachytherapy source and delivery system for use in conjunction with minimally invasive wedge resection of early-stage lung cancer.

Authors:  Kara Lynne Leonard; Thomas A DiPetrillo; John J Munro; David E Wazer
Journal:  Brachytherapy       Date:  2010-08-12       Impact factor: 2.362

6.  An EGSnrc investigation of the air-kerma strength, dose rate constant, and radial dose function of 125I brachytherapy sources.

Authors:  Sridhar Sahoo; T Palani Selvam
Journal:  Radiol Phys Technol       Date:  2009-07-11

7.  Monte Carlo simulations to assess the effects of tube current modulation on breast dose for multidetector CT.

Authors:  Erin Angel; Nazanin Yaghmai; Cecilia Matilda Jude; John J Demarco; Christopher H Cagnon; Jonathan G Goldin; Andrew N Primak; Donna M Stevens; Dianna D Cody; Cynthia H McCollough; Michael F McNitt-Gray
Journal:  Phys Med Biol       Date:  2009-01-06       Impact factor: 3.609

8.  Monte Carlo-based revised values of dose rate constants at discrete photon energies.

Authors:  T Palani Selvam; Vandana Shrivastava; Ghanashyam Chourasiya; D Appala Raju Babu
Journal:  J Med Phys       Date:  2014-01

9.  A seed specific dose kernel method for low-energy brachytherapy dosimetry.

Authors:  John J DeMarco; Timothy D Solberg; Nzhde Agazaryan
Journal:  J Appl Clin Med Phys       Date:  2003       Impact factor: 2.102

10.  Comparison of TG-43 dosimetric parameters of brachytherapy sources obtained by three different versions of MCNP codes.

Authors:  Neda Zaker; Mehdi Zehtabian; Sedigheh Sina; Craig Koontz; Ali S Meigooni
Journal:  J Appl Clin Med Phys       Date:  2016-03-08       Impact factor: 2.102

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.