Literature DB >> 12030553

Use of recovery coefficients as a test of system linearity of response in positron emission tomography (PET).

Bernd O Knoop1, Lilli Geworski, Michael Hofmann, Dieter L Munz, Wolfram H Knapp.   

Abstract

Quantitative determination of activity concentration has always been regarded as a goal of PET scanner design. Therefore, a linear response with respect to activity concentration is essential. To prove system linearity of response a test is proposed based on the determination of recovery coefficients (RC) for different object geometries. If all degrading effects, especially scatter and attenuation, are corrected to a sufficient degree of accuracy, the system behaves linearly resulting in a theoretical relationship between hot (HSRC) and cold spot recovery coefficients (CSRC). Therefore this relationship, applied to appropriate phantom data containing hot or cold spheres, combined with the constraints on asymptotic behaviour of RC can be used as a test of system linearity of response. After applying the system's standard corrections RC were determined using both 2D and 3D data acquisition modes. For both 2D and 3D data, HSRC directly measured showed an excellent agreement with the HSRC calculated from the CSRC. The analysis was extended to radionuclides of different positron ranges, to the effect of data smoothing, and to that of iterative reconstruction. The agreement between the RC determined under varying border conditions demonstrates the effectiveness of the corrections used in constituting system linearity. Therefore, the method proposed is used as a test of system linearity of response.

Mesh:

Year:  2002        PMID: 12030553     DOI: 10.1088/0031-9155/47/8/302

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Evaluation of a 3D point cloud tetrahedral tomographic reconstruction method.

Authors:  N F Pereira; A Sitek
Journal:  Phys Med Biol       Date:  2010-08-24       Impact factor: 3.609

2.  Iodine-124 PET dosimetry in differentiated thyroid cancer: recovery coefficient in 2D and 3D modes for PET(/CT) systems.

Authors:  Walter Jentzen; Reiner Weise; Jürgen Kupferschläger; Lutz Freudenberg; Wolfgang Brandau; Ronald Bares; Wolfgang Burchert; Andreas Bockisch
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-10-10       Impact factor: 9.236

3.  In vivo quantitation of intratumoral radioisotope uptake using micro-single photon emission computed tomography/computed tomography.

Authors:  Stephanie K Carlson; Kelly L Classic; Elizabeth M Hadac; Claire E Bender; Bradley J Kemp; Val J Lowe; Tanya L Hoskin; Stephen J Russell
Journal:  Mol Imaging Biol       Date:  2006 Nov-Dec       Impact factor: 3.484

4.  Visualization of the auditory pathway in rats with 18F-FDG PET activation studies based on different auditory stimuli and reference conditions including cochlea ablation.

Authors:  Martin Mamach; Mariella Kessler; Jens P Bankstahl; Florian Wilke; Lilli Geworski; Frank M Bengel; Simone Kurt; Georg Berding
Journal:  PLoS One       Date:  2018-10-02       Impact factor: 3.240

5.  Serotonin transporter binding is increased in Tourette syndrome with Obsessive Compulsive Disorder.

Authors:  K R Müller-Vahl; N Szejko; F Wilke; E Jakubovski; L Geworski; F Bengel; G Berding
Journal:  Sci Rep       Date:  2019-01-30       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.