Literature DB >> 12030542

Processing and analysis of in vivo high-resolution MR images of trabecular bone for longitudinal studies: reproducibility of structural measures and micro-finite element analysis derived mechanical properties.

D C Newitt1, B van Rietbergen, S Majumdar.   

Abstract

The authors have developed a system for the characterization of trabecular bone structure from high-resolution MR images. It features largely automated coil inhomogeneity correction, trabecular bone region segmentation, serial image registration, bone/marrow binarization, and structural calculation steps. The system addresses problems of efficiency and inter- and intraoperator variability inherent in previous analyses. The system is evaluated on repetitive scans of 8 volunteers for both two-dimensional (2D) apparent structure calculations and three-dimensional (3D) mechanical calculations using micro-finite element analysis. Coil correction methods based on a priori knowledge of the coil sensitivity and on low-pass filtering of the high-resolution mages are compared and found to perform similarly. Image alignment is found to cause small but significant changes in some structural parameters. Overall the automated system provides on the order of a 3-fold decrease in trained operator time over previous manual methods. Reproducibility is found to be dependent on image quality for most parameters. For 7 subjects with good image quality, reproducibility of 2-4% is found for 2D structural parameters, while 3D mechanical parameters vary by 4-9%, with percent standardized coefficients of variation in the ranges of 15-34% and 20-38% respectively.

Mesh:

Year:  2002        PMID: 12030542     DOI: 10.1007/s001980200027

Source DB:  PubMed          Journal:  Osteoporos Int        ISSN: 0937-941X            Impact factor:   4.507


  54 in total

1.  Performance of μMRI-Based virtual bone biopsy for structural and mechanical analysis at the distal tibia at 7T field strength.

Authors:  Yusuf A Bhagat; Chamith S Rajapakse; Jeremy F Magland; James H Love; Alexander C Wright; Michael J Wald; Hee Kwon Song; Felix W Wehrli
Journal:  J Magn Reson Imaging       Date:  2011-02       Impact factor: 4.813

2.  Bone microarchitecture assessment: current and future trends.

Authors:  Ralph Müller
Journal:  Osteoporos Int       Date:  2003-08-29       Impact factor: 4.507

Review 3.  Bone quality: where do we go from here?

Authors:  Mary L Bouxsein
Journal:  Osteoporos Int       Date:  2003-08-29       Impact factor: 4.507

4.  Cross-sectional DXA and MR measures of tibial periarticular bone associate with radiographic knee osteoarthritis severity.

Authors:  G H Lo; A M Tassinari; J B Driban; L L Price; E Schneider; S Majumdar; T E McAlindon
Journal:  Osteoarthritis Cartilage       Date:  2012-03-16       Impact factor: 6.576

5.  Trabecular structure analysis using C-arm CT: comparison with MDCT and flat-panel volume CT.

Authors:  Catherine M Phan; Eric A Macklin; Miriam A Bredella; Monica Dadrich; Paul Flechsig; Albert J Yoo; Joshua A Hirsch; Rajiv Gupta
Journal:  Skeletal Radiol       Date:  2010-07-25       Impact factor: 2.199

6.  Structural and mechanical parameters of trabecular bone estimated from in vivo high-resolution magnetic resonance images at 3 tesla field strength.

Authors:  Michael Jeffrey Wald; Jeremy Franklin Magland; Chamith Sudesh Rajapakse; Felix Werner Wehrli
Journal:  J Magn Reson Imaging       Date:  2010-05       Impact factor: 4.813

7.  Assessment of trabecular bone structure comparing magnetic resonance imaging at 3 Tesla with high-resolution peripheral quantitative computed tomography ex vivo and in vivo.

Authors:  R Krug; J Carballido-Gamio; A J Burghardt; G Kazakia; B H Hyun; B Jobke; S Banerjee; M Huber; T M Link; S Majumdar
Journal:  Osteoporos Int       Date:  2007-11-09       Impact factor: 4.507

8.  In vivo 7.0-tesla magnetic resonance imaging of the wrist and hand: technical aspects and applications.

Authors:  Klaus M Friedrich; Gregory Chang; Renata L R Vieira; Ligong Wang; Graham C Wiggins; Mark E Schweitzer; Ravinder R Regatte
Journal:  Semin Musculoskelet Radiol       Date:  2009-02-23       Impact factor: 1.777

9.  Gender differences in trabecular bone architecture of the distal radius assessed with magnetic resonance imaging and implications for mechanical competence.

Authors:  Martin Hudelmaier; A Kollstedt; E M Lochmüller; V Kuhn; F Eckstein; T M Link
Journal:  Osteoporos Int       Date:  2005-03-03       Impact factor: 4.507

10.  Compressive axial mechanical properties of rat bone as functions of bone volume fraction, apparent density and micro-ct based mineral density.

Authors:  Esther Cory; Ara Nazarian; Vahid Entezari; Vartan Vartanians; Ralph Müller; Brian D Snyder
Journal:  J Biomech       Date:  2009-12-08       Impact factor: 2.712

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.