Literature DB >> 12030347

Head-to-head comparison of fundamental, tissue harmonic and contrast harmonic imaging with or without an air-filled contrast agent, levovist, for endocardial border delineation in patients with poor quality images.

Hidetoshi Yoshitani1, Masaaki Takeuchi, Makoto Hirose, Chinami Miyazaki, Shinichiro Otani, Kazuo Sakamoto, Junichi Yoshikawa.   

Abstract

Recent developments in tissue harmonic imaging and intravenous contrast agents have enhanced left ventricular endocardial border delineation (EBD). In a total of 48 patients with poor quality images, apical 4- and 2-chamber views were obtained with fundamental, tissue harmonic and contrast harmonic imaging with or without intravenous Levovist, an air-filled contrast agent. The left ventricle (LV) was divided into 12 segments, and the EBD of each segment was scored: (1) not visible, (2) barely visible, (3) well delineated. The EBD index (EBDI), defined as the sum of the endocardial scores divided by 12 was obtained for each patient. Of a total of 576 LV segments, 231 were scored as 1 by fundamental imaging and that number decreased to 125 segments by tissue harmonic imaging and 116 segments by fundamental imaging with Levovist. The number of segments scored as 1 decreased to 38 segments by tissue harmonic imaging with Levovist, and to 29 segments by contrast harmonic imaging with Levovist. The EBDI by fundamental imaging was 1.85+/-0.29, which improved significantly with the addition of Levovist (2.10+/-0.36, p<0.001) and was nearly identical to that by tissue harmonic imaging (2.15+/-0.32, p=NS). Tissue and contrast harmonic imaging with Levovist further enhanced the EBDI (2.43+/-0.26, 2.51+/-0.27, respectively). Levovist enhances EBD, even in the fundamental mode, to the level obtained with tissue harmonic imaging. Tissue harmonic and contrast harmonic imaging are the best modalities for enhancing EBD after Levovist injection.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12030347     DOI: 10.1253/circj.66.494

Source DB:  PubMed          Journal:  Circ J        ISSN: 1346-9843            Impact factor:   2.993


  4 in total

1.  Safety of ultrasound contrast agents in the pediatric oncologic population: a single-institution experience.

Authors:  Jamie L Coleman; Fariba Navid; Wayne L Furman; M Beth McCarville
Journal:  AJR Am J Roentgenol       Date:  2014-05       Impact factor: 3.959

2.  Contrast-enhanced sonography of malignant pediatric abdominal and pelvic solid tumors: preliminary safety and feasibility data.

Authors:  M Beth McCarville; Sue C Kaste; Fredric A Hoffer; Raja B Khan; R Christopher Walton; Bruce S Alpert; Wayne L Furman; Chenghong Li; Xiaoping Xiong
Journal:  Pediatr Radiol       Date:  2012-01-17

3.  Impact of image quality on reliability of the measurements of left ventricular systolic function and global longitudinal strain in 2D echocardiography.

Authors:  Yasufumi Nagata; Yuichiro Kado; Takeshi Onoue; Kyoko Otani; Akemi Nakazono; Yutaka Otsuji; Masaaki Takeuchi
Journal:  Echo Res Pract       Date:  2018-02-05

4.  Development and validation of a novel image quality rating scale for echocardiography during cardiac arrest.

Authors:  Romolo Gaspari; Felipe Teran; Andrew Kamilaris; Timothy Gleeson
Journal:  Resusc Plus       Date:  2021-03-06
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.