Literature DB >> 12026921

Clinical relevance of standardization of endodontic files dimensions according to the ISO 3630-1 specification.

S Zinelis1, E A Magnissalis, J Margelos, T Lambrianidis.   

Abstract

The aim of this study was to examine the current status of standardization of endodontic instruments. Measurements of instrument dimensions were conducted on stainless steel H- and K-files (sizes 08-40), as well as on rotary-driven nickel titanium (NiTi) files (sizes 15-40), to determine the incidence and degree of deviation from ISO 3630-1, 1992 specification. In addition, the dimensions of sets of H- and K-files (sizes 08-25) were measured to identify discrepancies in dimensions among instruments within the same size per manufacturer. The percentage of difference in width were used to determine the graduation from each size to the next. None of the files tested complied with the ISO nominal size. All files were within the ISO tolerance limits. However, under such tolerance limits, there is a high possibility of either sizes overlapping or of great differences between two sequential sizes. These results may explain the clinical difficulty found in negotiating narrow and curved canals and may establish the need for a more comprehensive approach on the evaluation methods used in root-canal instrument dimension specifications.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12026921     DOI: 10.1097/00004770-200205000-00005

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  5 in total

1.  Taper preparation variability compared to current taper standards using computed tomography.

Authors:  Richard Gergi; Joe Abou Rjeily; Nada Osta; Joseph Sader; Alfred Naaman
Journal:  Int J Dent       Date:  2012-02-29

2.  A comparison of dimensional standard of several nickel-titanium rotary files.

Authors:  Ki-Won Kim; Kyung-Mo Cho; Se-Hee Park; Ki-Yeol Choi; Bekir Karabucak; Jin-Woo Kim
Journal:  Restor Dent Endod       Date:  2014-01-20

3.  Assessment of geometrical characteristics of dental endodontic micro-instruments utilizing X-ray micro computed tomography.

Authors:  Youssef S Al Jabbari; Peter Tsakiridis; George Eliades; Solaiman M Al-Hadlaq; Spiros Zinelis
Journal:  J Appl Oral Sci       Date:  2012 Nov-Dec       Impact factor: 2.698

4.  Nominal Size and Taper Analysis of Novel Metallurgy NiTi Files.

Authors:  Melita Islambasic; Marcelo Santos Coelho; Mary T Pettiette; Peter Z Tawil
Journal:  Eur Endod J       Date:  2016-12-07

5.  Assessment of consistency in the dimension of gutta-percha cones of ProTaper Next and WaveOne with their corresponding number files.

Authors:  Nitika Bajaj; Prashant Monga; Pardeep Mahajan
Journal:  Eur J Dent       Date:  2017 Apr-Jun
  5 in total