Literature DB >> 1202571

The physics of diagnostic ultrasound.

E U Buddemeyer.   

Abstract

Sound waves progress through a medium at a velocity that is characteristic of that medium. In a particular medium, wavelength and frequency are inversely related, so that short wavelengths can only be obtained at higher frequencies. A beam of sound will not be directional unless the object that is sending (or reflecting) it is at least several times longer than the wavelength. In tissue directional beams of 1 cm or less in width can be produced at frequencies of 1 MHz or more. Other things being equal, the higher the frequency, the narrower the beam. The attenuation of beams of sound in tissue at ultrasonic frequencies is directly and almost linearly related to frequency in that the higher the frequency, the greater the attenuation and the weaker the return signals. In choosing an operating frequency for a particular purpose, one must therefore bear in mind that the advantages of the higher frequencies (i.e., better resolution, both in range and azimuth) are obtained at the bost of a shorter effective range. Accordingly, one makes the best compromise by selecting the highest frequency that permits a range adequate for the purpose. In scanning the abdomens of adults where the range may be fairly long, a 2 MHz transducer is used. For cardiac studies in pediatric patients where the range is shorter and the structures smaller, a 5 MHz probe can be used. In the globe of the eye the structures are minute, the medium one in which losses are quite low and the range is very short, permitting the use of frequencies in the 10 to 20 MHz range.

Entities:  

Mesh:

Year:  1975        PMID: 1202571

Source DB:  PubMed          Journal:  Radiol Clin North Am        ISSN: 0033-8389            Impact factor:   2.303


  5 in total

Review 1.  Role of ultrasonography in oral and maxillofacial surgery: a review of literature.

Authors:  Kodali Rama Mohan; Nadella Koteswara Rao; Guttikonda Leela Krishna; Vedati Santosh Kumar; Nallamothu Ranganath; Uppaluru Vijaya Lakshmi
Journal:  J Maxillofac Oral Surg       Date:  2014-03-14

2.  Modern sonology and the bedside practitioner: evolution of ultrasound from curious novelty to essential clinical tool.

Authors:  S P Stawicki; D P Bahner
Journal:  Eur J Trauma Emerg Surg       Date:  2014-11-04       Impact factor: 3.693

3.  Hepatic abscess: ultrasound as an aid to diagnosis.

Authors:  T L Lawson
Journal:  Am J Dig Dis       Date:  1977-01

4.  A comparable study of the diagnostic performance of orbital ultrasonography and CBCT in patients with suspected orbital floor fractures.

Authors:  Masoumeh Johari; Mohammad Ali Ghavimi; Hediyeh Mahmoudian; Reza Javadrashid; Simin Mirakhor Samani; Daniel F Fouladi
Journal:  Dentomaxillofac Radiol       Date:  2016-05-04       Impact factor: 2.419

5.  The role of diagnostic ultrasound as a new diagnostic aid in oral and maxillofacial surgery.

Authors:  Siva Subramaniyam Venkataraman; Ramraj Jayabalan Aravind; Thangavelu Kavin
Journal:  J Pharm Bioallied Sci       Date:  2012-08
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.