Instrumentation for contrast echocardiography.

Peter N Burns1.   

Abstract

A number of new imaging methods have been developed specifically for use with ultrasound contrast agents. These methods rely on the peculiar behavior of microbubbles in an ultrasound field. At low incident acoustic pressures (reflected by the mechanical index, MI) microbubbles emit harmonics. These can be detected using harmonic or pulse inversion imaging. At higher MI, bubbles are disrupted, emitting a strong, nonlinear echo. Harmonic power Doppler methods are able to detect this echo, offering the most sensitive method for the detection of microbubble at the perfusion level. Although the first images of myocardial perfusion were made using this disruption method, it requires intermittent imaging with interframe intervals of up to 6 heart beats. Pulse inversion Doppler imaging is a newer method that is able to detect the nonlinear component of bubble echoes at a very low MI, thereby making possible real-time myocardial perfusion imaging. An understanding of the behavior of bubbles during an imaging examination is an essential prerequisite to its success in clinical practice.

Mesh:

Substances:

Year:  2002        PMID: 12022934     DOI: 10.1046/j.1540-8175.2002.00241.x

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  6 in total

1.  Potential pitfalls of visualization of myocardial perfusion by myocardial contrast echocardiography with harmonic gray scale B-mode and power Doppler imaging.

Authors:  Hisashi Masugata; Kazushi Yukiiri; Yuichiro Takagi; Koji Ohmori; Katsufumi Mizushige; Masakazu Kohno
Journal:  Int J Cardiovasc Imaging       Date:  2004-04       Impact factor: 2.357

2.  [Summary of technical principles of contrast sonography and future perspectives].

Authors:  C Greis
Journal:  Radiologe       Date:  2011-06       Impact factor: 0.635

3.  Optimization of ultrasound contrast agents with computational models to improve selection of ligands and binding strength.

Authors:  Timothy M Maul; Drew D Dudgeon; Michael T Beste; Daniel A Hammer; John S Lazo; Flordeliza S Villanueva; William R Wagner
Journal:  Biotechnol Bioeng       Date:  2010-12-01       Impact factor: 4.530

4.  Optimization of contrast-to-tissue ratio by adaptation of transmitted ternary signal in ultrasound pulse inversion imaging.

Authors:  Sébastien Ménigot; Jean-Marc Girault
Journal:  Comput Math Methods Med       Date:  2013-03-20       Impact factor: 2.238

5.  A general framework for modeling sub- and ultraharmonics of ultrasound contrast agent signals with MISO volterra series.

Authors:  Fatima Sbeity; Sébastien Ménigot; Jamal Charara; Jean-Marc Girault
Journal:  Comput Math Methods Med       Date:  2013-03-10       Impact factor: 2.238

6.  Contrast improvement in sub- and ultraharmonic ultrasound contrast imaging by combining several hammerstein models.

Authors:  Fatima Sbeity; Sébastien Ménigot; Jamal Charara; Jean-Marc Girault
Journal:  Int J Biomed Imaging       Date:  2013-11-07
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.