Literature DB >> 12022539

Myocardial preservation using Celsior solution in cardiac transplantation: early results and 5-year follow-up of a multicenter prospective study of 70 cardiac transplantations.

Jean-Paul Remadi1, Olivier Baron, Jean C Roussel, Oussana Al Habash, Michele Treilhaud, Philippe Despins, Daniel Duveau, Jean-Luc Michaud.   

Abstract

BACKGROUND: Several storage methods using a wide variety of extracellular or intracellular solutions applied either as continuous perfusion, intermittent perfusion, or simple immersion of the heart have been commonly used. We have performed a prospective randomized multicenter study of 70 cardiac transplantation recipients to evaluate the Celsior solution for cardiac preservation.
METHODS: Seventy consecutive patients were included in this trial and received a cardiac graft arrested and preserved with Celsior. The first follow-up period was 1 month. The mean age of the recipients was 49 years (range, 28 to 66 years), and 81.7% were male. The main disease was nonobstructive cardiomyopathy (64.3%). The age range of donors was between 14 and 56 years with a mean of 33 years. The majority of grafts (73%) were stored in 1 L of Celsior. A midterm follow-up at 5 years was performed and was 100% complete.
RESULTS: The operative mortality (<30-day) rate was 6 of 70 (8.6%). Sixty-three patients (90%) had at least satisfactory hemodynamic measurements on day 2. The first postoperative echocardiograms showed good myocardial performance for 90% of the grafts. Actuarial survival rate at 5 years was 75% +/- 5.1%.
CONCLUSIONS: The use of Celsior in cardiac transplantation was safe and very effective. This solution proved very valuable in at-risk patients.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12022539     DOI: 10.1016/s0003-4975(02)03424-0

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  4 in total

1.  Celsior versus University of Wisconsin preserving solutions for liver transplantation: postreperfusion syndrome and outcome of a 5-year prospective randomized controlled study.

Authors:  Francisco A García-Gil; María T Serrano; Lorena Fuentes-Broto; Juan Arenas; José J García; Antonio Güemes; Vanesa Bernal; Ana Campillo; Carlos Sostres; Juan J Araiz; Pablo Royo; Miguel A Simón
Journal:  World J Surg       Date:  2011-07       Impact factor: 3.352

2.  A novel method of measuring cardiac preservation injury demonstrates University of Wisconsin solution is associated with less ischemic necrosis than Celsior in early cardiac allograft biopsy specimens.

Authors:  Timothy J George; George J Arnaoutakis; Claude A Beaty; Ashish S Shah; John V Conte; Marc K Halushka
Journal:  J Heart Lung Transplant       Date:  2011-12-30       Impact factor: 10.247

Review 3.  Preservation solutions for cardiac and pulmonary donor grafts: a review of the current literature.

Authors:  Nicholas Latchana; Joshua R Peck; Bryan Whitson; Sylvester M Black
Journal:  J Thorac Dis       Date:  2014-08       Impact factor: 2.895

4.  High-risk heart grafts: effective preservation with Celsior solution.

Authors:  Luca Salvatore De Santo; Cristiano Amarelli; Gianpaolo Romano; Alessandro Della Corte; Ciro Maiello; Bruno Giannolo; Claudio Marra; Marisa De Feo; Michelangelo Scardone; Maurizio Cotrufo
Journal:  Heart Vessels       Date:  2006-03       Impact factor: 2.037

  4 in total