Porous-surfaced dental implants in the partially edentulous maxilla: assessment for subclinical mobility.

Douglas Deporter1, Reynaldo Todescan, Nicole Riley.   

Abstract

Fifty patients received 151 short, porous-surfaced implants in the partially edentulous maxilla. Periotest values (PTV) were recorded at baseline and after 6 months and 1 and 2 years. For this, prostheses were removed and a standard abutment attached and tightened (20-Ncm force) to each implant. Data analysis indicated significant relationships between time in function vs PTV and implant diameter (3.5, 4.1, or 5.0 mm) vs PTV There was no relationship between PTV and implant length. PTVs were more favorable in the posterior than anterior maxilla, and better PTVs were obtained with nonsplinted as opposed to splinted implants.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12019714

Source DB:  PubMed          Journal:  Int J Periodontics Restorative Dent        ISSN: 0198-7569            Impact factor:   1.840


  2 in total

1.  Design of dental implants, influence on the osteogenesis and fixation.

Authors:  Luana M R Vasconcellos; Marize V Oliveira; Mário L A Graça; Luis G O Vasconcellos; Carlos A A Cairo; Yasmin R Carvalho
Journal:  J Mater Sci Mater Med       Date:  2008-03-18       Impact factor: 3.896

2.  Histomorphometric analysis of pure titanium implants with porous surface versus rough surface.

Authors:  Aline Scalone Brentel; Luana Marotta Reis de Vasconcellos; Marize Varella Oliveira; Mário Lima de Alencastro Graça; Luis Gustavo Oliveira de Vasconcellos; Carlos Alberto Alves Cairo; Yasmin Rodarte Carvalho
Journal:  J Appl Oral Sci       Date:  2006-06       Impact factor: 2.698

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.