Literature DB >> 12018648

Interaction of array of finite electrodes with layered biological tissue: effect of electrode size and configuration.

L M Livshitz1, J Mizrahi, P D Einziger.   

Abstract

A hybrid scheme, combining image series and moment method has been utilized for the calculation of the intramuscular three-dimensional (3-D) current density (CD) distribution and potential field transcutaneously excited by an electrode array. The model permits one to study the effect of tissue electrical properties and electrode placement on the CD distribution. The isometric recruitment curve (IRC) of the muscle was used for parameter estimation and model verification, by comparison with experimentally obtained IRCs of functional electrical stimulation (FES)-activated quadriceps muscle of paraplegic subjects. Sensitivity of the calculated IRC to parameters such as tissue conductivity, electrode size, and configuration was verified. The resulting model demonstrated characteristic features that were similar to those of experimentally obtained data. The model IRCs were insensitive to the electrode size; however, the inclusion of the bone-fascia layer significantly increased the intramuscular CD and, consequently, increased the IRC slope. Of the different configurations studied, a four-electrode array proved advantageous because, in this case, the CD between the electrodes was more evenly distributed, providing better resistance to fatigue. However, due to the steeper linear portion of the IRC, this configuration suffered from a somewhat reduced controllability of the muscle.

Entities:  

Mesh:

Year:  2001        PMID: 12018648     DOI: 10.1109/7333.1000115

Source DB:  PubMed          Journal:  IEEE Trans Neural Syst Rehabil Eng        ISSN: 1534-4320            Impact factor:   3.802


  5 in total

Review 1.  A review of the responses of two- and three-dimensional engineered tissues to electric fields.

Authors:  Marie Hronik-Tupaj; David L Kaplan
Journal:  Tissue Eng Part B Rev       Date:  2012-01-26       Impact factor: 6.389

Review 2.  Neuromuscular electrical stimulation for skeletal muscle function.

Authors:  Barbara M Doucet; Amy Lam; Lisa Griffin
Journal:  Yale J Biol Med       Date:  2012-06-25

3.  Evolution of Surface Motor Activation Zones in Hemiplegic Patients During 20 Sessions of FES Therapy with Multi-pad Electrodes.

Authors:  Jovana Malešević; Matija Štrbac; Milica Isaković; Vladimir Kojić; Ljubica Konstantinović; Aleksandra Vidaković; Suzana Dedijer; Miloš Kostić; Thierry Keller
Journal:  Eur J Transl Myol       Date:  2016-06-13

4.  Comparison of Proximally Versus Distally Placed Spatially Distributed Sequential Stimulation Electrodes in a Dynamic Knee Extension Task.

Authors:  Marco Laubacher; Efe A Aksöz; Stuart Binder-Macleod; Kenneth J Hunt
Journal:  Eur J Transl Myol       Date:  2016-06-13

5.  Electric Factors in Wound Healing.

Authors:  Paulo Luiz Farber; Felipe Contoli Isoldi; Lydia Masako Ferreira
Journal:  Adv Wound Care (New Rochelle)       Date:  2020-10-06       Impact factor: 4.947

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.