Literature DB >> 12016026

Quantitation of 2-chlorovinylarsonous acid in human urine by automated solid-phase microextraction--gas chromatography--mass spectrometry.

Joe V Wooten1, David L Ashley, Antonia M Calafat.   

Abstract

Lewisite [dichloro(2-chlorovinyl)arsine] is a highly toxic chemical warfare agent with vesicant properties. The accidental exposure to lewisite or its intentional use as a chemical terrorism weapon are a public health threat and warrant investigations for the development of analytical methods to detect biomarkers of exposure to lewisite. Under aqueous conditions, lewisite rapidly hydrolyzes to the non-volatile 2-chlorovinylarsonous acid (CVAA). We have developed a sensitive, simple, and automated method for measuring CVAA in human urine. The assay is based on the use of solid-phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS) after derivatization of the CVAA with 1,3-propanedithiol (PDT). The volatile CVAA-PDT is adsorbed onto a SPME fiber and analyzed by GC-MS. The assay was validated on human urine samples spiked with CVAA to determine the accuracy, precision, and limit of detection (LOD). The LOD was 7.4 pg in 1 ml of urine.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12016026     DOI: 10.1016/s1570-0232(02)00069-7

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  1 in total

1.  Hand-portable gas chromatograph-toroidal ion trap mass spectrometer (GC-TMS) for detection of hazardous compounds.

Authors:  Jesse A Contreras; Jacolin A Murray; Samuel E Tolley; Joseph L Oliphant; H Dennis Tolley; Stephen A Lammert; Edgar D Lee; Douglas W Later; Milton L Lee
Journal:  J Am Soc Mass Spectrom       Date:  2008-07-03       Impact factor: 3.109