Literature DB >> 12014490

Free surface nickel in CE-marked and non-CE-marked spectacle frames.

G Walsh1, J W C Mitchell.   

Abstract

Three hundred and ninety-five new frames were tested for evidence of nickel release using dimethylglyoxime and ammonia. For areas of CE-marked frames in direct contact with the skin a considerable improvement was found over the previous such survey by the authors, carried out before the widespread introduction of CE marking. However, free nickel was found in 6.5% of CE-marked metal frames (excluding titanium and titanium alloy) in such areas and a majority of half joints. Some titanium alloy frames also tested positive for nickel in areas in contact with the skin.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12014490     DOI: 10.1046/j.1475-1313.2002.00018.x

Source DB:  PubMed          Journal:  Ophthalmic Physiol Opt        ISSN: 0275-5408            Impact factor:   3.117


  2 in total

1.  [Allergic potential of titanium implants].

Authors:  A Schuh; P Thomas; W Kachler; J Göske; L Wagner; U Holzwarth; R Forst
Journal:  Orthopade       Date:  2005-04       Impact factor: 1.087

2.  The fine scratches of the spectacle frames and the allergic contact dermatitis.

Authors:  In Su Kim; Kwang Ho Yoo; Myeung Nam Kim; Hyuck Ki Hong; Yeon Shik Choi; Young Chang Jo; Beom Joon Kim; Ju Suk Lee
Journal:  Ann Dermatol       Date:  2013-05-10       Impact factor: 1.444

  2 in total