Literature DB >> 12009459

Impedimetric immunosensor using avidin-biotin for antibody immobilization.

O Ouerghi1, A Touhami, N Jaffrezic-Renault, C Martelet, H Ben Ouada, S Cosnier.   

Abstract

The potentialities of an electrodeposited biotinylated polypyrrole film as an immobilisation matrix for the fabrication of impedimetric immunosensors are described. Biotinylated antibody (anti-human IgG), used as a model system, was attached to free biotin groups on the electrogenerated polypyrrole film using avidin as a coupling reagent. This immobilization method allows to obtain a highly reproducible and stable device. The resulting immunosensor has a linear dynamic range of 10-80 ng ml(-1) of antigen and a detection limit of 10 pg ml(-1). Furthermore, this immunosensor exhibited minor loss in response after two regeneration steps.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12009459     DOI: 10.1016/s1567-5394(02)00029-4

Source DB:  PubMed          Journal:  Bioelectrochemistry        ISSN: 1567-5394            Impact factor:   5.373


  4 in total

1.  Label-free toxin detection by means of time-resolved electrochemical impedance spectroscopy.

Authors:  Changhoon Chai; Paul Takhistov
Journal:  Sensors (Basel)       Date:  2010-01-18       Impact factor: 3.576

2.  Functional epitope core motif of the Anaplasma marginale major surface protein 1a and its incorporation onto bioelectrodes for antibody detection.

Authors:  Paula S Santos; Rafael Nascimento; Luciano P Rodrigues; Fabiana A A Santos; Paula C B Faria; João R S Martins; Ana G Brito-Madurro; João M Madurro; Luiz R Goulart
Journal:  PLoS One       Date:  2012-03-12       Impact factor: 3.240

3.  A fumonisins immunosensor based on polyanilino-carbon nanotubes doped with palladium telluride quantum dots.

Authors:  Milua Masikini; Stephen N Mailu; Abebaw Tsegaye; Njagi Njomo; Kerileng M Molapo; Chinwe O Ikpo; Christopher Edozie Sunday; Candice Rassie; Lindsay Wilson; Priscilla G L Baker; Emmanuel I Iwuoha
Journal:  Sensors (Basel)       Date:  2014-12-30       Impact factor: 3.576

4.  Screen Printed Based Impedimetric Immunosensor for Rapid Detection of Escherichia coli in Drinking Water.

Authors:  Martina Cimafonte; Andrea Fulgione; Rosa Gaglione; Marina Papaianni; Rosanna Capparelli; Angela Arciello; Sergio Bolletti Censi; Giorgia Borriello; Raffaele Velotta; Bartolomeo Della Ventura
Journal:  Sensors (Basel)       Date:  2020-01-03       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.