Literature DB >> 12009182

Methodology of three-dimensional determination of root surface roughness.

Thomas Kocher1, Natascha Langenbeck, Michael Rosin, Olaf Bernhardt.   

Abstract

In comparing and evaluating the instruments that are used in root debridement, roughness constitutes a standard variable that is assessed. The purpose of this study was to describe the conditions and requirements for the three-dimensional roughness measurements of tooth roots using a laser profilometer. Impressions were made of 60 instrumented and 12 untreated root surfaces, which were then measured using a dynamically focussing optical profilometer (Mikrofocus, UBM, Karlsruhe, Germany). To separate roughness from the form of the tooth, a low pass filter was applied. This meant that the longer wavelengths - which roughly approximated the root forms - were subtracted from the measured profile. We then used an individualized Fourier transformation to define the threshold at which roughness becomes waviness. Roughness parameters were Ra (average roughness) and Rz (average roughness in the z dimension) for two- and three-dimensional measurements. To describe the requirements for the measurement, we studied the effect of pixel density and the field size on the average roughness value, Ra. We found that Ra increases with pixel density until 400 per mm is reached, after which it does not change meaningfully. Furthermore, Ra is highly dependent upon the area of the field to be scanned, increasing in line with the area, and does not approach one value within the surface available on one tooth. The correlation coefficients between the two-dimensional and three-dimensional Ra and Rz values ranged from 0.7 to 0.8. We conclude that roughness values are strongly dependent on the measurement conditions and the results of one study cannot be directly compared to another. In addition, it was found that two-dimensional measurements are sufficient for characterizing root surfaces.

Entities:  

Mesh:

Year:  2002        PMID: 12009182     DOI: 10.1034/j.1600-0765.2002.00341.x

Source DB:  PubMed          Journal:  J Periodontal Res        ISSN: 0022-3484            Impact factor:   4.419


  3 in total

1.  Effects of Root Debridement With Hand Curettes and Er:YAG Laser on Chemical Properties and Ultrastructure of Periodontally-Diseased Root Surfaces Using Spectroscopy and Scanning Electron Microscopy.

Authors:  Reza Amid; Gholam Ali Gholami; Masoud Mojahedi; Maryam Aghalou; Mohsen Gholami; Mahdieh Mirakhori
Journal:  J Lasers Med Sci       Date:  2017-03-28

2.  Effect of carbamide peroxide and hydrogen peroxide on enamel surface: an in vitro study.

Authors:  Thaer Abouassi; Martin Wolkewitz; Petra Hahn
Journal:  Clin Oral Investig       Date:  2010-07-10       Impact factor: 3.573

3.  A comparison of magnetostrictive and piezoelectric ultrasonic scaling devices: an in vitro study.

Authors:  Hojatollah Yousefimanesh; Maryam Robati; Mahdi Kadkhodazadeh; Reza Molla
Journal:  J Periodontal Implant Sci       Date:  2012-12-31       Impact factor: 2.614

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.