Literature DB >> 12008012

Reliability of rapid diagnostic tests for HIV variant infection.

Maria Makuwa1, Sandrine Souquière, Marie Therèse Niangui, Pierre Rouquet, Cristian Apetrei, Pierre Roques, François Simon.   

Abstract

The sensitivity of one ELISA method, six HIV-1/HIV-2 rapid screening tests, and one confirmatory test was evaluated in comparison with a third-generation EIA method (taken as the 'gold standard') and Western blot on well-characterized panels of sera. HIV diversity was represented by 50 HIV-1 group M subtype A to H, nine HIV-1 group O, 12 HIV-2, two HIV1+2 positive and six indeterminate Western blot profiles. Sensitivity during HIV-1 seroconversion was studied on 39 serial samples collected from six patients during early primary infection. Serial samples obtained from two primates during experimental primary SIV infection were used to mimic HIV-2 seroconversion samples. The sensitivity ranged from 100 to 94.6% according to the test. During seroconversion, rapid tests became positive 2-8 days later than the third-generation EIA. This reveals a major limitation of rapid tests, which are being recommended for use in developing countries. The lack of sensitivity seen during early HIV-1 seroconversion and/or limited specificity in some of the evaluated tests present serious limitations to their use in countries with high HIV incidence and variability. It is suggested that, as soon as possible, less sensitive rapid tests for blood bank screening should be abandoned in favor of highly sensitive rapid tests and/or more robust, more sensitive and cheaper ELISAs. These results stress the need for better screening tools and specific local evaluations.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12008012     DOI: 10.1016/s0166-0934(02)00026-5

Source DB:  PubMed          Journal:  J Virol Methods        ISSN: 0166-0934            Impact factor:   2.014


  6 in total

1.  Use of rapid and conventional testing technologies for human immunodeficiency virus type 1 serologic screening in a rural Kenyan reference laboratory.

Authors:  Ginamarie Foglia; G Donald Royster; K Monique Wasunna; Rukia Kibaya; Jennifer A Malia; Eva K Calero; Warren Sateren; Philip O Renzullo; Merlin L Robb; Deborah L Birx; Nelson L Michael
Journal:  J Clin Microbiol       Date:  2004-08       Impact factor: 5.948

Review 2.  The Diagnosis of HIV Infection in Infants and Children.

Authors:  Alireza Abdollahi; Hana Saffar
Journal:  Iran J Pathol       Date:  2016

3.  Assessment of rapid diagnostic tests and fourth-generation Enzyme-Linked Immunosorbent Assays in the screening of Human Immunodeficiency and Hepatitis B virus infections among first-time blood donors in Libreville (Gabon).

Authors:  Jean Marie Eko Mba; Cyrille Bisseye; Landry Erik Mombo; Jophrette Mireille Ntsame Ndong; Schella Carlaye Mbina Ekayeng; Calixte Bengone; Bertrand M'batchi; Bolni Marius Nagalo
Journal:  J Clin Lab Anal       Date:  2018-11-28       Impact factor: 2.352

4.  Assessment of rapid tests for detection of human immunodeficiency virus-specific antibodies in recently infected individuals.

Authors:  Brian Louie; Ernest Wong; Jeffrey D Klausner; Sally Liska; Frederick Hecht; Terri Dowling; Martha Obeso; Susan S Phillips; Mark W Pandori
Journal:  J Clin Microbiol       Date:  2008-01-30       Impact factor: 5.948

5.  Sensitivity of five rapid HIV tests on oral fluid or finger-stick whole blood: a real-time comparison in a healthcare setting.

Authors:  Juliette Pavie; Anne Rachline; Bénédicte Loze; Laurence Niedbalski; Constance Delaugerre; Eric Laforgerie; Jean-Christophe Plantier; Willy Rozenbaum; Sylvie Chevret; Jean-Michel Molina; François Simon
Journal:  PLoS One       Date:  2010-07-19       Impact factor: 3.240

6.  The evaluation of accuracy of serial rapid HIV test algorithm in the diagnosis of HIV antibodies among pregnant women in south east Nigeria.

Authors:  Ikechukwu Innocent Mbachu; Gerald Udigwe; Ikechebelu Joseph; Okonkwo John; Umeononihu Osita Samuel; Ugboaja Joseph; Mbachu Chioma Ngozi
Journal:  BMC Res Notes       Date:  2015-10-12
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.