Literature DB >> 12007774

Development and validation of a plasma assay for acyclovir using high-performance capillary electrophoresis with sample stacking.

Hung C Vo1, Paul A Henning, Daniel T Leung, Stephen L Sacks.   

Abstract

A sensitive plasma assay for acyclovir has been developed and validated. Acyclovir was separated from plasma components using Oasis HLB columns. Separation was obtained with no plasma interference using micellar electrokinetic chromatography (175 mM SDS) and hydroxypropyl-beta-cyclodextrin (100 mM) in 90 mM borate buffer (pH 8.8) containing 0.2% NaCl. High sensitivity was achieved by large volume sample introduction and stacking. The linear range was from 20 to 10000 ng/ml with a limit of quantitation of 20 ng/ml. This method is a viable alternative to HPLC because of its high separation and sensitivity, reproducibility, and adaptability to other nucleoside analogs.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12007774     DOI: 10.1016/s1570-0232(02)00116-2

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  5 in total

1.  Enhanced Oral Bioavailability of Epalrestat SBE7-β-CD Complex Loaded Chitosan Nanoparticles: Preparation, Characterization and in-vivo Pharmacokinetic Evaluation.

Authors:  Zunaira Alvi; Muhammad Akhtar; Arshad Mahmood; Nisar Ur-Rahman; Imran Nazir; Hadia Sadaquat; Muhammad Ijaz; Shahzada Khurram Syed; Muhammad Khurram Waqas; Yi Wang
Journal:  Int J Nanomedicine       Date:  2021-12-29

2.  Inadequacy of plasma acyclovir levels at delivery in patients with genital herpes receiving oral acyclovir suppressive therapy in late pregnancy.

Authors:  Daniel T Leung; Paul A Henning; Emily C Wagner; Audrey Blasig; Anna Wald; Stephen L Sacks; Lawrence Corey; Deborah M Money
Journal:  J Obstet Gynaecol Can       Date:  2009-12

3.  Determination of Acyclovir in Human Plasma Samples by HPLC Method with UV Detection: Application to Single-Dose Pharmacokinetic Study.

Authors:  Dragica Zendelovska; Suzana Simeska; Emilija Atanasovska; Kalina Georgievska; Igor Kikerkov; Nikola Labachevski; Krume Jakovski; Trajan Balkanov
Journal:  Open Access Maced J Med Sci       Date:  2015-01-22

4.  A newfangled study using risk silhouette and uncertainty approximation for quantification of acyclovir in diverse formulation.

Authors:  Karan Mittal; Riddhish Patadia; Chintan Vora; Rajashree C Mashru
Journal:  J Pharm Anal       Date:  2014-06-12

5.  Synergistic Effect of ZnO Nanoparticles and Carbon Nanotube and Polymeric Film on Electrochemical Oxidation of Acyclovir.

Authors:  Ghasem Karim-Nezhad; Arezu Sarkary; Zeynab Khorablou; Parisa Seyed Dorraji
Journal:  Iran J Pharm Res       Date:  2018       Impact factor: 1.696

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.