Literature DB >> 12007123

Separation of enantiomers by nanoliquid chromatography and capillary electrochromatography using a bonded cellulose trisphenylcarbamate stationary phase.

Xiaoming Chen1, Hanfa Zou, Mingliang Ye, Zengzi Zhang.   

Abstract

A cellulose trisphenylcarbamate-bonded chiral stationary phase was applied to nano-liquid chromatography (nano-LC) and capillary electrochromatography (CEC) with nonaqueous and aqueous solutions as the mobile phases. Several chiral compounds were successfully resolved on the prepared phase by nano-LC. The applicability of nonaqueous CEC on a cellulose derivative stationary phase was investigated with the organic solvents methanol, hexane, 2-propanol, and tetrahydrofuran (THF) containing acetic acid, as well as triethylamine as the mobile phases. Enantiomers of warfarin and praziquantel were baseline-resolved with plate numbers of 82,300 and 38,800 plates/m, respectively, for the first eluting enantiomer. The influence of applied voltage, concentration of nonpolar solvent, apparent pH, and buffer concentration in the mobile phase on the electroosmotic flow (EOF) and the mobility of the enantiomers was evaluated. Enantioseparations of trans-stilbene oxide and praziquantel were also achieved in aqueous CEC with plate numbers of 111,100 and 107,400 plates/m, respectively, for the first eluting enantiomer. A comparison between nonaqueous CEC and aqueous CEC based on a cellulose trisphenylcarbamate stationary phase was discussed. Pressure-assisted CEC was examined for the chiral separation of praziquantel and faster analysis with high enantioselectivity was acquired with the proper pressurization of the inlet vial.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12007123     DOI: 10.1002/1522-2683(200205)23:9<1246::AID-ELPS1246>3.0.CO;2-C

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  3 in total

Review 1.  Chiral separation principles in chromatographic and electromigration techniques.

Authors:  Gerald Gübitz; Martin G Schmid
Journal:  Mol Biotechnol       Date:  2006-02       Impact factor: 2.695

2.  High Throughput Analysis of Chiral Compounds Using Capillary Electrochromatography (CEC) and CEC-Mass Spectrometry with Cellulose Based Stationary Phases.

Authors:  William Bragg; Shahab A Shamsi
Journal:  Sep Sci Technol       Date:  2013       Impact factor: 2.475

3.  Sulfated and sulfonated polysaccharide as chiral stationary phases for capillary electrochromatography and capillary electrochromatography-mass spectrometry.

Authors:  Jie Zheng; William Bragg; Jingguo Hou; Na Lin; Sekar Chandrasekaran; Shahab A Shamsi
Journal:  J Chromatogr A       Date:  2008-12-06       Impact factor: 4.759

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.