Biomechanical comparison of effects of supraspinatus tendon detachments, tendon defects, and muscle retractions.

A M Halder1, S W O'Driscoll, G Heers, N Mura, M E Zobitz, K N An, R Kreusch-Brinker.   

Abstract

BACKGROUND: Rotator cuff ruptures are frequently associated with loss of strength of the shoulder. However, the characteristics of the rotator cuff tear that are responsible for the loss of force generation and transmission have not yet been identified. The purpose of this study was to compare the effects of supraspinatus tendon detachments, tendon defects, and muscle retractions on in vitro force transmission by the rotator cuff to the humerus.
METHODS: The rotator cuff tendons from ten cadaver shoulders were loaded proportionally to the respective cross-sectional areas of their muscles. A fiberglass rod was cemented into the medullary canal of the humerus and connected to a three-component load cell for the measurement of the forces transmitted by the rotator cuff to the humerus. This study was performed with the humerus in a hanging arm position and with various sizes of supraspinatus tendon detachments, tendon defects, and muscle retractions.
RESULTS: Detachment or creation of a defect involving one-third or two-thirds of the supraspinatus tendon resulted in a minor reduction in the force transmitted by the rotator cuff (< or =5%), while detachment or creation of a defect involving the whole tendon resulted in a moderate reduction (11% and 17%, respectively). Simulated muscle retraction involving one-third, two-thirds, and the whole tendon resulted in losses of torque measuring 19%, 36%, and 58%, respectively. Side-to-side repair of the one-third and two-thirds defects nearly restored the force transmission capability, whereas a deficit remained after side-to-side repair following complete resection.
CONCLUSIONS: Our results support the rotator cable concept and correspond to the clinical observation that patients with a small rupture of the rotator cuff may present without a loss of shoulder strength. Muscle retraction is potentially an important factor responsible for loss of shoulder strength following large rotator cuff ruptures. CLINICAL RELEVANCE: Supraspinatus muscle retraction diminishes glenohumeral abduction torque significantly more than either a defect in the tendon or a simple detachment of the tendon from the tuberosity. In cases of irreparable defects, side-to-side repair may be worthwhile to restore muscle tension and the integrity of the rotator cable.

Entities:  

Mesh:

Year:  2002        PMID: 12004021     DOI: 10.2106/00004623-200205000-00013

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  27 in total

1.  The comparison of patellar tendon-bone autografting and free flexor-tendon autografting in infraspinatus defect of the shoulder: biomechanical and histological evaluation in a sheep model.

Authors:  Muhittin Sener; Mehmet A Altay; Celal Baki; Ahmet U Turhan; Umit Cobanoglu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2004-02-06       Impact factor: 4.342

2.  [Arthroscopic reconstruction of the rotor cuff].

Authors:  G J Bauer; B Kniesel
Journal:  Unfallchirurg       Date:  2006-08       Impact factor: 1.000

3.  Comparison between single-row and double-row rotator cuff repair: a biomechanical study.

Authors:  Giuseppe Milano; Andrea Grasso; Donatella Zarelli; Laura Deriu; Mario Cillo; Carlo Fabbriciani
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-08-08       Impact factor: 4.342

4.  What is the best glenoid configuration in onlay reverse shoulder arthroplasty?

Authors:  Alexandre Lädermann; Patrick J Denard; Pascal Boileau; Alain Farron; Pierric Deransart; Gilles Walch
Journal:  Int Orthop       Date:  2018-02-28       Impact factor: 3.075

Review 5.  Joint-preserving treatment options for irreparable rotator cuff tears.

Authors:  P Valenti
Journal:  Orthopade       Date:  2018-02       Impact factor: 1.087

6.  Additive fiber-cerclages in proximal humeral fractures stabilized by locking plates: no effect on fracture stabilization and rotator cuff function in human shoulder specimens.

Authors:  Christine Voigt; Christof Hurschler; Louise Rechi; Rolf Vosshenrich; Helmut Lill
Journal:  Acta Orthop       Date:  2009-08       Impact factor: 3.717

7.  [Effect of additive fiber cerclage of the rotator cuff in angle-stable plate-stabilized proximal humeral fractures: a biomechanical study of human shoulder specimens].

Authors:  C Voigt; C Hurschler; J Althainz; R Vosshenrich; H Lill
Journal:  Unfallchirurg       Date:  2008-07       Impact factor: 1.000

8.  Rotator cuff tendon connections with the rotator cable.

Authors:  Madis Rahu; Ivo Kolts; Elle Põldoja; Kristo Kask
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-05-02       Impact factor: 4.342

9.  Instantaneous helical axis estimation of glenohumeral kinematics: The impact of rotator cuff pathology.

Authors:  Rebekah L Lawrence; Matthew C Ruder; Roger Zauel; Michael J Bey
Journal:  J Biomech       Date:  2020-07-02       Impact factor: 2.712

10.  Patterns of tear progression for asymptomatic degenerative rotator cuff tears.

Authors:  Jay D Keener; Jason E Hsu; Karen Steger-May; Sharlene A Teefey; Aaron M Chamberlain; Ken Yamaguchi
Journal:  J Shoulder Elbow Surg       Date:  2015-12       Impact factor: 3.019

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.