Literature DB >> 11999151

Reliability of binocular vision measurements used in the classification of convergence insufficiency.

Michael W Rouse1, Eric Borsting, Paul N Deland.   

Abstract

PURPOSE: To evaluate the reliability of binocular vision measurements used in the classification of convergence insufficiency.
METHODS: Two examiners tested 20 fifth and sixth graders in a school setting who passed a screening of visual acuity, refraction, and binocularity. The tests, conducted using a standard protocol, consisted of von Graefe near heterophoria (NH), phorometric positive fusional vergence (PFV), nearpoint of convergence (NPC), and monocular pushup accommodative amplitude (AA). Each examiner measured each child three consecutive times for each test, on two separate occasions, spaced approximately 1 week apart. Intraexaminer and interexaminer agreement was assessed using intraclass correlation coefficients (ICC), the median absolute difference (MAD), and the coefficient of repeatability (COR).
RESULTS: The within-session reliability of the NH (ICC: 0.95 to 0.99), NPC (ICC: 0.94 to 0.98), and AA (ICC: 0.88 to 0.95) were good, whereas the PFV was less reliable (ICC: 0.71 to 0.94). The intraexaminer reliability between sessions was good for the NPC (ICC: 0.92 and 0.89), less reliable for NH (ICC: 0.81 and 0.81) and AA (ICC: 0.89 and 0.69), and much less reliable for PFV break (ICC: 0.59 and 0.53). Typical between-session PFV differences (MAD) were between 3 and 4 delta, whereas the COR differences were as large as 12 delta.
CONCLUSIONS: Three of the four measures (NH, NPC, and AA) often used in the classification of convergence insufficiency generally have good within-session and between-session reliability. The PFV break was found to have only fair reliability with clinically significant differences between sessions. The large potential test-retest differences found could complicate clinical decision-making in regards to diagnosis and treatment.

Entities:  

Mesh:

Year:  2002        PMID: 11999151     DOI: 10.1097/00006324-200204000-00012

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  18 in total

1.  Reliability of acuities determined with the sweep visual evoked potential (sVEP).

Authors:  William H Ridder; Anna Tong; Theresa Floresca
Journal:  Doc Ophthalmol       Date:  2012-01-20       Impact factor: 2.379

2.  Repeatability intraexaminer and agreement in amplitude of accommodation measurements.

Authors:  B Antona; F Barra; A Barrio; E Gonzalez; I Sanchez
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-09-13       Impact factor: 3.117

3.  2017 Glenn A. Fry Award Lecture: Establishing an Evidence-based Literature for Vision Therapy - A 25-year Journey.

Authors:  Mitchell M Scheiman
Journal:  Optom Vis Sci       Date:  2018-08       Impact factor: 1.973

4.  The Convergence Insufficiency Neuro-mechanism in Adult Population Study (CINAPS) Randomized Clinical Trial: Design, Methods, and Clinical Data.

Authors:  Tara L Alvarez; Mitchell Scheiman; Elio M Santos; Cristian Morales; Chang Yaramothu; John Vito D'Antonio-Bertagnolli; Bharat B Biswal; Suril Gohel; Xiaobo Li
Journal:  Ophthalmic Epidemiol       Date:  2019-10-22       Impact factor: 1.648

5.  Ten-year changes in fusional vergence, phoria, and nearpoint of convergence in myopic children.

Authors:  Heather Anderson; Karla K Stuebing; Karen D Fern; Ruth E Manny
Journal:  Optom Vis Sci       Date:  2011-09       Impact factor: 1.973

6.  Randomized clinical trial of treatments for symptomatic convergence insufficiency in children.

Authors: 
Journal:  Arch Ophthalmol       Date:  2008-10

7.  Near Point of Convergence After a Sport-Related Concussion: Measurement Reliability and Relationship to Neurocognitive Impairment and Symptoms.

Authors:  Kelly L Pearce; Alicia Sufrinko; Brian C Lau; Luke Henry; Michael W Collins; Anthony P Kontos
Journal:  Am J Sports Med       Date:  2015-10-09       Impact factor: 6.202

8.  OculoMotor Assessment Tool Test Procedure and Normative Data.

Authors:  Chang Yaramothu; Christopher J Morris; John Vito d'Antonio-Bertagnolli; Tara L Alvarez
Journal:  Optom Vis Sci       Date:  2021-06-01       Impact factor: 2.106

9.  Diagnostic validity of clinical signs associated with a large exophoria at near.

Authors:  Pilar Cacho-Martínez; Angel García-Muñoz; María Teresa Ruiz-Cantero
Journal:  J Ophthalmol       Date:  2013-06-17       Impact factor: 1.909

10.  The repeatability and reproducibility of four techniques for measuring horizontal heterophoria: Implications for clinical practice.

Authors:  Nicola S Anstice; Bianca Davidson; Bridget Field; Joyce Mathan; Andrew V Collins; Joanna M Black
Journal:  J Optom       Date:  2020-08-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.