Literature DB >> 11996058

Pre-scaled two-parameter Gauss-Newton image reconstruction to reduce property recovery imbalance.

Paul M Meaney1, Navin K Yagnamurthy, Keith D Paulsen.   

Abstract

Gauss-Newton image reconstruction in microwave imaging can be formulated in terms of a single complex quantity, the wave number squared (k2), with the understanding that the relative permittivity and conductivity images can be extracted afterwards through a simple constitutive relationship. However, this approach ignores the fact that the magnitude of the average real and imaginary components can be considerably out of balance depending on the operating frequency and tissue characteristics which can inadvertently imbalance the process in favour of one parameter over the other. In an effort to achieve property recovery which is balanced, we introduce a pre-scaling procedure at the property update stage of the reconstruction. Utilization of this concept in conjunction with our two-step regularization process for both simulation and phantom experiments demonstrates that the penalty term weighting parameters for the optimal mean-squared property errors for the two recovered distributions (relative permittivity and conductivity) together with that yielding the lowest least-squared electric field error coincide only when the scaling is applied. The scheme provides a means for simultaneous optimization of the two permittivity and conductivity images.

Mesh:

Substances:

Year:  2002        PMID: 11996058     DOI: 10.1088/0031-9155/47/7/308

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Heterogeneous Anthropomorphic Phantoms with Realistic Dielectric Properties for Microwave Breast Imaging Experiments.

Authors:  Alireza Mashal; Fuqiang Gao; Susan C Hagness
Journal:  Microw Opt Technol Lett       Date:  2011-08       Impact factor: 1.392

2.  Three-dimensional microwave breast imaging: dispersive dielectric properties estimation using patient-specific basis functions.

Authors:  David W Winters; Jacob D Shea; Panagiotis Kosmas; Barry D Van Veen; Susan C Hagness
Journal:  IEEE Trans Med Imaging       Date:  2009-02-10       Impact factor: 10.048

3.  Heterogeneous breast phantom development for microwave imaging using regression models.

Authors:  Camerin Hahn; Sima Noghanian
Journal:  Int J Biomed Imaging       Date:  2012-04-08

4.  On the Use of Focused Incident Near-Field Beams in Microwave Imaging.

Authors:  Nozhan Bayat; Puyan Mojabi
Journal:  Sensors (Basel)       Date:  2018-09-17       Impact factor: 3.576

5.  Effects of the Plastic of the Realistic GeePS-L2S-Breast Phantom.

Authors:  Tomas Rydholm; Andreas Fhager; Mikael Persson; Shireen D Geimer; Paul M Meaney
Journal:  Diagnostics (Basel)       Date:  2018-09-01
  5 in total