Literature DB >> 11996035

Hydroxyapatite-coated Ti-6Al-4V part 2: the effects of post-deposition heat treatment at low temperatures.

A K Lynn1, D L DuQuesnay.   

Abstract

The present investigation explores the effects of a 90-h post-deposition annealing treatment at 400 degrees C in air on the crystallographic and chemical properties of a plasma-sprayed hydroxyapatite (HA) coating, the thickness and composition of the interfacial oxide layer, and the fatigue behaviour of the underlying Ti-6Al-4V substrate. X-ray diffraction analysis revealed that significant recovery of the crystalline HA structure occurred as a result of the treatment, however, as compared with results obtained through treatment at higher temperatures, recovery obtained through use of the present treatment was incomplete. X-ray photoelectron spectroscopy analysis showed no changes in the constituents of the oxide layer, with the oxide species TiO2, Al2O3, V2O5, V2O3, and VO2 present on both the as-sprayed and the heat-treated substrates. A change in film thickness was observed, however, as evidenced by a change in colour from opaque bronze to dark purple. The fatigue resistance of the substrate was found to be significantly reduced by the heat treatment, with the lives of heat-treated coupons with coatings of all thicknesses closely resembling those of as-sprayed coupons with thick HA coatings and uncoated stress-relieved coupons presented in Part I of this study. Stress relief was identified as the most likely cause of these reductions.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11996035     DOI: 10.1016/s0142-9612(01)00320-9

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  4 in total

1.  Cytocompatibility of calcium phosphate coatings deposited by an ArF pulsed laser.

Authors:  Y Hashimoto; M Kawashima; R Hatanaka; M Kusunoki; H Nishikawa; S Hontsu; M Nakamura
Journal:  J Mater Sci Mater Med       Date:  2007-07       Impact factor: 3.896

2.  Cytocompatibility of calcium phosphate coatings deposited by an ArF pulsed laser.

Authors:  Y Hashimoto; M Kawashima; R Hatanaka; M Kusunoki; H Nishikawa; S Hontsu; M Nakamura
Journal:  J Mater Sci Mater Med       Date:  2007-06-28       Impact factor: 3.896

Review 3.  Dental implant systems.

Authors:  Yoshiki Oshida; Elif B Tuna; Oya Aktören; Koray Gençay
Journal:  Int J Mol Sci       Date:  2010-04-12       Impact factor: 5.923

4.  An Investigation on the Wear Resistance and Fatigue Behaviour of Ti-6Al-4V Notched Members Coated with Hydroxyapatite Coatings.

Authors:  Reza H Oskouei; Khosro Fallahnezhad; Sushmitha Kuppusami
Journal:  Materials (Basel)       Date:  2016-02-16       Impact factor: 3.623

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.