Literature DB >> 11995865

Disinfection of wastewater by hydrogen peroxide or peracetic acid: development of procedures for measurement of residual disinfectant and application to a physicochemically treated municipal effluent.

Monika Wagner1, Daina Brumelis, Ronald Gehr.   

Abstract

The Montreal Urban Community Wastewater Treatment Plant (MUCWTP) located in Montreal. Quebec, Canada, uses physicochemical treatment processes prior to discharging wastewater into the St. Lawrence River via an outfall tunnel of 2 hours retention time. Although chlorination facilities exist, they are not being used, and the MUCWTP is seeking alternative methods for disinfection to achieve a 2- to 3-log fecal coliform reduction. Liquid chemical disinfectants were attractive options because of their low capital costs. This led to an investigation of the feasibility of using hydrogen peroxide or peracetic acid. A method for measuring peroxycompounds (hydrogen peroxide or peracetic acid plus hydrogen peroxide) was developed using the peroxidase-based oxidation of 2,2'-azino-bis(3-ethylbenz-thiazoline-6-sulfuric acid) diammonium salt (ABTS) with hydrogen peroxide. The validity of the method was confirmed using effluent from the MUCWTP. Recovery was higher than 90% for peracetic acid levels as low as 1.0 mg/L. Quenching of hydrogen peroxide was achieved with 50-mg/L catalase; quenching of peracetic acid was achieved with 100 mg/L of sodium thiosulfate, followed by 50 mg/L of catalase. Batch disinfection tests were conducted on MUCWTP effluent. Hydrogen peroxide and peracetic acid in wastewater over time could be modeled as a second-order decay, with the decay "constant" being a function of the initial concentration of peroxycompounds. This function was the same for both hydrogen peroxide and peracetic acid, possibly indicating similar decomposition pathways in wastewater matrices. Disinfection was modeled using a modified Hom equation. Required doses of hydrogen peroxide to reach the target fecal coliform levels ranged from 106 to 285 mg/L, with the higher doses occurring when ferric chloride instead of alum was used as the coagulant. Hence, hydrogen peroxide was infeasible as a disinfectant for this application. On the other hand, the peracetic acid dose needed to achieve the target fecal coliform level was only 0.6 to 1.6 mg/L. Therefore, peracetic acid seems to be a promising disinfectant for physicochemical or primary effluent, or combined sewer overflows.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11995865     DOI: 10.2175/106143002x139730

Source DB:  PubMed          Journal:  Water Environ Res        ISSN: 1061-4303            Impact factor:   1.946


  12 in total

1.  Influence of industrial contamination in municipal secondary effluent disinfection by UV/H2O2.

Authors:  Jacqueline A Malvestiti; Renato F Dantas
Journal:  Environ Sci Pollut Res Int       Date:  2019-03-21       Impact factor: 4.223

2.  Treatment of Arctic wastewater by chemical coagulation, UV and peracetic acid disinfection.

Authors:  Ravi Kumar Chhetri; Ewa Klupsch; Henrik Rasmus Andersen; Pernille Erland Jensen
Journal:  Environ Sci Pollut Res Int       Date:  2017-02-16       Impact factor: 4.223

3.  A field-portable colorimetric method for the measurement of peracetic acid vapors: a comparison of glass and plastic impingers.

Authors:  Angela L Stastny; Amos Doepke; Robert P Streicher
Journal:  J Occup Environ Hyg       Date:  2022-06-28       Impact factor: 3.359

4.  Impact of UV and peracetic acid disinfection on the prevalence of virulence and antimicrobial resistance genes in uropathogenic Escherichia coli in wastewater effluents.

Authors:  Basanta Kumar Biswal; Ramzi Khairallah; Kareem Bibi; Alberto Mazza; Ronald Gehr; Luke Masson; Dominic Frigon
Journal:  Appl Environ Microbiol       Date:  2014-06       Impact factor: 4.792

5.  Inactivation of Bacillus anthracis spores by a combination of biocides and heating under high-temperature short-time pasteurization conditions.

Authors:  Sa Xu; Theodore P Labuza; Francisco Diez-Gonzalez
Journal:  Appl Environ Microbiol       Date:  2008-04-04       Impact factor: 4.792

6.  The use of peracetic acid for estrogen removal from urban wastewaters: E2 as a case study.

Authors:  Rita Maurício; Joana Jorge; Rita Dias; João P Noronha; Leonor Amaral; Michiel A Daam; António P Mano; Mário S Diniz
Journal:  Environ Monit Assess       Date:  2020-01-15       Impact factor: 2.513

7.  Disinfection of raw wastewater and activated sludge effluent using Fenton like reagent.

Authors:  Hassan Aslani; Ramin Nabizadeh; Mahmood Alimohammadi; Alireza Mesdaghinia; Kazem Nadafi; Reza Nemati; Maryam Ghani
Journal:  J Environ Health Sci Eng       Date:  2014-12-14

8.  Biocidal and Sporicidal Efficacy of Pathoster(®) 0.35% and Pathoster(®) 0.50% Against Bacterial Agents in Potential Bioterrorism Use.

Authors:  Antonio Candeliere; Emanuele Campese; Adelia Donatiello; Stefania Pagano; Michela Iatarola; Francesco Tolve; Leonardo Antonino; Antonio Fasanella
Journal:  Health Secur       Date:  2016 Jul-Aug

9.  Colorimetric Quantification Methods for Peracetic Acid together with Hydrogen Peroxide for Water Disinfection Process Control.

Authors:  Ravi Kumar Chhetri; Kamilla Marie Speht Kaarsholm; Henrik Rasmus Andersen
Journal:  Int J Environ Res Public Health       Date:  2020-06-28       Impact factor: 3.390

Review 10.  Using agro-industrial wastes for the cultivation of microalgae and duckweeds: Contamination risks and biomass safety concerns.

Authors:  Giorgos Markou; Liang Wang; Jianfeng Ye; Adrian Unc
Journal:  Biotechnol Adv       Date:  2018-04-17       Impact factor: 14.227

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.