Abstract

To reduce the time needed for clamping or circulatory arrest (or both) during substitution of a prosthesis for the thoracic aorta, we developed an expandable device that can be used with any commercially available prosthetic graft to enable sutureless aortic anastomosis. Improvements upon a previous version of the device include the use of nickel-titanium alloy (Nitinol) instead of stainless steel. This, together with an improved wire-looping design, now enables continuous control of diameter, even when the device is in contact with blood. A further improvement consists of 4 metallic hooks on the outer surface, which enable firm fixation to the aortic stump. In March 2001, a 47-year-old man was admitted to our institution for evaluation of left upper-lobe bronchogenic adenocarcinoma that had infiltrated the distal aortic arch and upper descending aorta. Re-staging of the neoplasm ruled out distant metastasis. We resected the infiltrated aortic wall en bloc with the upper lobe. The expandable device enabled the distal anastomosis of the aortic prosthesis to be performed easily, in less than 3 minutes. The main advantages of this device are an easier, quicker anastomosis and the absolute prevention of suture-line hemorrhage (no suture line). The expandable device overcomes the drawbacks of the intraluminal ringed prosthesis used in the past.

Entities:  

Mesh:

Year:  2002        PMID: 11995854      PMCID: PMC101273     

Source DB:  PubMed          Journal:  Tex Heart Inst J        ISSN: 0730-2347


  10 in total

1.  Combined resection of T4 lung cancer with invasion of the descending thoracic aorta.

Authors:  S Shimokawa; S Watanabe; K Sakasegawa
Journal:  Ann Thorac Surg       Date:  2000-03       Impact factor: 4.330

2.  Aortic replacement with sutureless intraluminal grafts.

Authors:  G M Lemole
Journal:  Tex Heart Inst J       Date:  1990

3.  Prosthesis for aortic arch substitution.

Authors:  S Nazari; S Salvi; A Aluffi; E Visconti; G Rescigno; P Buniva
Journal:  Ann Thorac Surg       Date:  1997-11       Impact factor: 4.330

4.  Expandable prosthesis for sutureless anastomosis in thoracic aorta prosthetic substitution.

Authors:  S Nazari; F Luzzana; C Banfi; Z Mourad; S Salvi; A Gaspari; F Nazari-Coerezza
Journal:  Eur J Cardiothorac Surg       Date:  1996       Impact factor: 4.191

Review 5.  Cerebrospinal fluid drainage in thoracoabdominal aortic surgery.

Authors:  J S Coselli; S A LeMaire; Z C Schmittling; C Köksoy
Journal:  Semin Vasc Surg       Date:  2000-12       Impact factor: 1.000

6.  A new predictive model for adverse outcomes after elective thoracoabdominal aortic aneurysm repair.

Authors:  S A LeMaire; C C Miller; L D Conklin; Z C Schmittling; C Köksoy; J S Coselli
Journal:  Ann Thorac Surg       Date:  2001-04       Impact factor: 4.330

7.  [Surgical indication in lung cancer and evaluation of extended combined resection].

Authors:  Y Nishimura; S Iwata; A Adachi; R Hayashida; A Hayashi; R Yo; M Sugiyama; Y Tanaka; T Koga; S Edakuni
Journal:  Kyobu Geka       Date:  1988-09

8.  [Combined resection of the descending aorta for lung cancer with aortic invasion].

Authors:  K Kodama; D Doi; M Higashiyama; H Yokouchi; T Kabuto; T Kobayashi; T Hiraishi
Journal:  Kyobu Geka       Date:  1995-05

9.  T4 lung tumors with infiltration of the thoracic aorta: is an operation reasonable?

Authors:  W Klepetko; W Wisser; T Bîrsan; P Mares; S Taghavi; N Kupilik; E Wolner
Journal:  Ann Thorac Surg       Date:  1999-02       Impact factor: 4.330

10.  Improved results for dissecting aneurysms. Intraluminal sutureless prosthesis.

Authors:  G M Lemole; M D Strong; P M Spagna; N P Karmilowicz
Journal:  J Thorac Cardiovasc Surg       Date:  1982-02       Impact factor: 5.209

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.