Literature DB >> 11995

In vivo measurements of oxyhaemoglobin saturation by a fiberoptic catheter. The effects of variations in pH and haematocrit.

F Tremolieres, F Lecompte, M Sinet, A Chirico, J Bech, J M Vallois, M C Blayo, J J Pocidalo.   

Abstract

The development of plastic fiberoptic catheters, cheaper and less fragile than glass ones, has enabled the more widespread use of oxyhaemoglobin saturation (SO2) monitoring. They allow direct determinations of SO2 to be made, using reflection spectrophotometry. The purpose of the present work was to evaluate the accuracy of SO2 measurements as provided by these catheters. The studies were performed in dogs, with large variations of SO2, acid-base balance and haematocrit levels.

Entities:  

Mesh:

Substances:

Year:  1976        PMID: 11995     DOI: 10.1007/BF00624612

Source DB:  PubMed          Journal:  Eur J Intensive Care Med        ISSN: 0340-0964


  13 in total

1.  CLINICAL APPLICATIONS OF AN IMPROVED, RAPIDLY RESPONDING FIBEROPTIC CATHETER.

Authors:  P L FROMMER; J ROSS; D T MASON; J H GAULT; E BRAUNWALD
Journal:  Am J Cardiol       Date:  1965-05       Impact factor: 2.778

2.  In vivo studies with an intravascular and intracardiac reflection oximeter.

Authors:  Y ENSON; W A BRISCOE; M L POLANYI; A COURNAND
Journal:  J Appl Physiol       Date:  1962-05       Impact factor: 3.531

3.  Cardiac output measurement with a simplified thermodilution technique. Comparison with the Fick method.

Authors:  L Sibille; R Prasquier; J M Vallois; C Gaudebout; J J Pocidalo
Journal:  Biomedicine       Date:  1975-02-28

4.  [Microdetermination of blood oxygen, using a physical technic (coulometry)].

Authors:  M C Blayo; M Sinet; C Joubin
Journal:  Pathol Biol (Paris)       Date:  1973-01

5.  Fibre optic reflection photometry on blood.

Authors:  G A Mook; P Osypka; R E Sturm; E H Wood
Journal:  Cardiovasc Res       Date:  1968-04       Impact factor: 10.787

6.  Variations of the optical parameters of red blood cell with wavelength & oxygen saturation.

Authors:  M K Moaveni
Journal:  Indian J Biochem Biophys       Date:  1973-06       Impact factor: 1.918

7.  Clinical studies with a solid state fiberoptic oximeter.

Authors:  J S Cole; W E Martin; P W Cheung; C C Johnson
Journal:  Am J Cardiol       Date:  1972-03       Impact factor: 2.778

8.  In vivo monitoring with a fiber optic catheter.

Authors:  J B Taylor; B Lown; M Polanyi
Journal:  JAMA       Date:  1972-08-14       Impact factor: 56.272

9.  A solid state fiberoptics oximeter.

Authors:  C C Johnson; R D Palm; D C Stewart; W E Martin
Journal:  J Assoc Adv Med Instrum       Date:  1971 Mar-Apr

10.  Fiber optics for continuous in vivo monitoring of oxygen saturation.

Authors:  D C Harrison; N S Kapany; H A Miller; N Silbertrust; W L Henry; R P Drake
Journal:  Am Heart J       Date:  1966-06       Impact factor: 4.749

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.