Comparison of insertion time and pullout strength between self-tapping and non-self-tapping AO 4.5-mm cortical bone screws in adult equine third metacarpal bone.

C Renee Andrea1, Susan M Stover, Larry D Galuppo, Ken T Taylor, Peter C Rakestraw.   

Abstract

OBJECTIVE: To compare screw insertion characteristics and pullout mechanical properties between self-tapping (ST) and non-self-tapping (NST) AO 4.5-mm cortical bone screws in adult equine third metacarpal bone (MC3). STUDY
DESIGN: In vitro biomechanical experiment. ANIMALS OR SAMPLE POPULATION: Seven pairs of adult equine MC3.
METHODS: Bicortical holes were drilled transversely in proximal metaphyseal, diaphyseal, and distal metaphyseal locations of paired MC3. NST screws were inserted in pre-tapped holes in 3 sites of one bone pair, and ST screws were inserted in non-tapped holes of contralateral MC3. Tapping and screw insertion times and maximum torques were measured. Screw pullout mechanical properties were determined.
RESULTS: Screw insertion time was longer for ST screws. Total time for tapping and insertion (total insertion time) was over twice as long for NST screws. Statistically significant differences were not observed between screws for any pullout mechanical property. From pullout tests, diaphyseal locations had significantly stiffer and stronger structure than metaphyseal locations. Pullout failure more commonly occurred because of screw breakage than bone failure. Bone failure and bone comminution were more commonly associated with ST screws. Bone failure sites had pullout failure loads that were 90% of screw failure sites.
CONCLUSIONS: NST and ST 4.5-mm-diameter cortical bone screws have similar pullout mechanical properties from adult equine MC3. ST screws require less than half the total insertion time of NST screws. CLINICAL RELEVANCE: Use of ST 4.5-mm-diameter cortical bone screws should be considered for repair of adult equine MC3 fractures; however, bone failures at screw sites should be monitored. Copyright 2002 by The American College of Veterinary Surgeons

Entities:  

Mesh:

Year:  2002        PMID: 11994845     DOI: 10.1053/jvet.2002.32398

Source DB:  PubMed          Journal:  Vet Surg        ISSN: 0161-3499            Impact factor:   1.495


  3 in total

1.  Analysis of stress induced by screws in the vertebral fixation system.

Authors:  Sarah Fakher Fakhouri; Marcos Massao Shimano; Cleudmar Amaral de Araújo; Helton Luiz Aparecido Defino; Antônio Carlos Shimano
Journal:  Acta Ortop Bras       Date:  2014       Impact factor: 0.513

2.  Biomechanical evaluation of peak reverse torque (PRT) in a dynamic compression plate-screw construct used in a goat tibia segmental defect model.

Authors:  Remigiusz M Grzeskowiak; Carrie Wheeler; Elizabeth Taylor; James Lillich; James Roush; Alexandru S Biris; David E Anderson
Journal:  BMC Vet Res       Date:  2019-09-05       Impact factor: 2.741

3.  Effect of cyclic loading on the stability of screws placed in the locking plates used to bridge segmental bone defects.

Authors:  Remigiusz M Grzeskowiak; Laura R Freeman; David P Harper; David E Anderson; Pierre-Yves Mulon
Journal:  J Orthop Res       Date:  2020-09-09       Impact factor: 3.494

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.