UNLABELLED: In this study, we evaluated the potential of (99m)Tc-hexakis-2-methoxyisobutylisonitrile (MIBI) for detecting bone metastases in comparison with a conventional bone tracer.
METHODS: (99m)Tc-MIBI and (99m)Tc-hydroxymethylene diphosphonate (HMDP) scans were obtained from 99 patients with proven malignant diseases and suspected bone metastases. We compared 373 lesions that showed abnormal uptake on (99m)Tc-MIBI scans or (99m)Tc-HMDP scans (or both).
RESULTS: Bone metastases were confirmed in 334 of 373 lesions. Thirty-nine lesions on (99m)Tc-HMDP scans had false-positive findings, but only 2 of these lesions had false-positive findings on (99m)Tc-MIBI scans. (99m)Tc-MIBI and (99m)Tc-HMDP scans were equivalent in 168 of 334 lesions (50.3%). (99m)Tc-MIBI scans correctly detected more lesions than (99m)Tc-HMDP scans: 284 lesions (85.0%) versus 218 lesions (65.3%) (P < 0.005), respectively. (99m)Tc-MIBI scans showed a markedly higher sensitivity for detecting metastases in the femur and humerus compared with (99m)Tc-HMDP scans: 97 of 98 lesions (99.0%) versus 35 of 98 lesions (35.7%) (P < 0.005) and 21 of 22 lesions (95.5%) versus 11 of 22 lesions (50.0%) (P < 0.005), respectively. (99m)Tc-HMDP scans of 17 patients showed no abnormal images. However, (99m)Tc-MIBI scans correctly detected bone metastases, and subsequent development of multiple lesions was observed on follow-up (99m)Tc-HMDP scans of 15 patients. (99m)Tc-MIBI scans were superior to (99m)Tc-HMDP scans in the detection of metastases attributed to breast cancer, multiple myeloma, and hepatoma. On the contrary, (99m)Tc-MIBI scans were less sensitive than (99m)Tc-HMDP scans for detecting bone metastases attributed to prostate cancer in the other skeletal sites except for femur and humerus.
CONCLUSION: (99m)Tc-MIBI scans have better sensitivity for detecting bone metastases and provide more specific complementary findings than conventional bone scans. (99m)Tc-MIBI accumulation attributed to bone marrow metastases may occur at an early stage, before the bone remodeling process in the surrounding bone can be detected on conventional bone scans.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11994520

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  2 in total

1.  The Role of Routine Whole Volume SPECT Reconstruction in Comparison to Cine Raw Data in the Detection of Extracardiac Uptake on Myocardial Perfusion Scans.

Authors:  M Maharaj; N A Korowlay
Journal:  World J Nucl Med       Date:  2011-01

2.  Comparison of Technetium-99m-MIBI imaging with MRI for detection of spine involvement in patients with multiple myeloma.

Authors:  Siroos Mirzaei; Martin Filipits; Andrea Keck; Walter Bergmayer; Peter Knoll; Horst Koehn; Heinz Ludwig; Martin Pecherstorfer
Journal:  BMC Nucl Med       Date:  2003-12-11
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.