Literature DB >> 11993766

Performance of an in situ passive sampling system for metals in stormwater.

Lena Björklund Blom1, Gregory M Morrison, Jenny Kingston, Graham A Mills, Richard Greenwood, Thomas J R Pettersson, Sebastien Rauch.   

Abstract

A passive sampler has been developed and is demonstrated in situ for urban runoff. The passive sampler is compared to conventional composite (time-dependent and flow-weighted) bottle sampling during and between storm events. The sampling was carried out at established stormwater stations; before and after a stormwater detention pond. In situ deployment of the passive sampler provides the metal concentrations, corresponding to the electrochemically available fraction of total metal, for time-dependent samples collected in parallel. The sampler provides improved accuracy compared to bottle sampling because contamination during sample transport and handling is minimised. Laboratory handling is reduced by direct analysis of the accumulated metals on the receiving membrane by laser ablation inductively coupled plasma mass spectrometry. Passive sampling also solves the problem of metal speciation change during transport to the laboratory, which is a potential problem for bottle samples. The low cost and convenience of the passive sampler and subsequent analysis should allow significantly more extensive spatial and temporal monitoring of metals in the aquatic environment than has previously been possible.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11993766     DOI: 10.1039/b200135g

Source DB:  PubMed          Journal:  J Environ Monit        ISSN: 1464-0325


  4 in total

1.  Presence of active pharmaceutical ingredients in the continuum of surface and ground water used in drinking water production.

Authors:  Heidi Ahkola; Sirkku Tuominen; Sanja Karlsson; Noora Perkola; Timo Huttula; Sami Saraperä; Aki Artimo; Taina Korpiharju; Lauri Äystö; Päivi Fjäder; Timo Assmuth; Kirsi Rosendahl; Taina Nysten
Journal:  Environ Sci Pollut Res Int       Date:  2017-09-29       Impact factor: 4.223

Review 2.  Overview of passive Chemcatcher sampling with SPE pretreatment suitable for the analysis of NPEOs and NPs.

Authors:  Heidi Ahkola; Sirpa Herve; Juha Knuutinen
Journal:  Environ Sci Pollut Res Int       Date:  2012-09-15       Impact factor: 4.223

3.  Study of different Chemcatcher configurations in the monitoring of nonylphenol ethoxylates and nonylphenol in aquatic environment.

Authors:  Heidi Ahkola; Sirpa Herve; Juha Knuutinen
Journal:  Environ Sci Pollut Res Int       Date:  2014-04-06       Impact factor: 4.223

4.  Estimation of Measurement Uncertainties for the DGT Passive Sampler Used for Determination of Copper in Water.

Authors:  Jesper Knutsson; Sebastien Rauch; Gregory M Morrison
Journal:  Int J Anal Chem       Date:  2014-09-01       Impact factor: 1.885

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.