Effect of phantom voxelization in CT simulations.

Andrew L Goertzen1, Freek J Beekman, Simon R Cherry.   

Abstract

In computer simulations of x-ray CT systems one can either use continuous geometrical descriptions for phantoms or a voxelized representation. The voxelized approach allows arbitrary phantoms to be defined without being confined to geometrical shapes. The disadvantage of the voxelized approach is that inherent errors are introduced due to the phantom voxelization. To study effects of phantom discretization, analytical CT simulations were run for a fan-beam geometry with phantom voxel sizes ranging from 0.0625 to 2 times the reconstructed pixel size and noise levels corresponding to 10(3) - 10(7) photons per detector pixel prior to attenuation. The number of rays traced per detector element was varied from 1 to 16. Differences in the filtered backprojection images caused by changing the phantom matrix sizes and number of rays traced were assessed by calculating the difference between reconstructions based on the finest matrix and coarser matrix simulations. In noise free simulations, all phantom matrix sizes produced a measurable difference in comparison with the finest phantom matrix used. When even a small amount of noise was added to the projection data, the differences due to the phantom discretization were masked by the noise, and in all cases there was almost no improvement by using a phantom matrix that was more than twice as fine as the reconstruction matrix. No substantial improvement was achieved by tracing more than 4 rays per detector pixel.

Entities:  

Mesh:

Year:  2002        PMID: 11991120     DOI: 10.1118/1.1461841

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

Review 1.  Current status and new horizons in Monte Carlo simulation of X-ray CT scanners.

Authors:  Habib Zaidi; Mohammad Reza Ay
Journal:  Med Biol Eng Comput       Date:  2007-07-05       Impact factor: 2.602

Review 2.  Modelling the physics in the iterative reconstruction for transmission computed tomography.

Authors:  Johan Nuyts; Bruno De Man; Jeffrey A Fessler; Wojciech Zbijewski; Freek J Beekman
Journal:  Phys Med Biol       Date:  2013-06-05       Impact factor: 3.609

3.  Analytical expressions for the reconstructed image of a homogeneous cylindrical sample exhibiting a beam hardening artifact in X-ray computed tomography.

Authors:  Tsukasa Nakano; Yoshito Nakashima
Journal:  J Xray Sci Technol       Date:  2018       Impact factor: 1.535

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.