Literature DB >> 11982825

The importance of convective transport.

Francesco Locatelli1, Celestina Manzoni, Salvatore Di Filippo.   

Abstract

BACKGROUND: Despite technological advances in dialysis equipment and modalities, survival, morbidity, and quality of life of hemodialysis patients are still severely affected by acute intradialytic and long-term complications, possibly related to the treatment itself. Convective treatments, such as high-flux hemodialysis, hemodiafiltration, and hemofiltration are increasingly suggested as further improvements over standard diffusive hemodialysis. The membranes used for these techniques are high-flux semisynthetic and synthetic membranes. Characteristics of these membranes are high permeability, which allows convective removal of water and electrolytes and higher clearance of middle and large molecular weight solutes, and high biocompatibility, which minimizes the "inflammatory response" secondary to interactions between blood and the artificial material of the hemodialysis system.
METHODS: With the specific aim of verifying the superiority of convective treatments in reducing morbidity and mortality, we performed a review of the published literature.
RESULTS: Some epidemiological studies suggest that convective treatments reduce morbidity and mortality among dialysis patients. However, the results of the published prospective randomized controlled trials are conflicting. Moreover, since convective treatments are usually performed with synthetic biocompatible membranes, it is hard to separate the effect of convection from the effect of biocompatibility.
CONCLUSIONS: To finally assess the effect of high-flux membranes on morbidity and mortality, the results of two randomized, controlled clinical trials (HEMO study and MPO study) specifically designed with this aim are needed.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11982825     DOI: 10.1046/j.1523-1755.61.s80.21.x

Source DB:  PubMed          Journal:  Kidney Int Suppl        ISSN: 0098-6577            Impact factor:   10.545


  3 in total

1.  Internal filtration in dialyzers with different membrane permeabilities.

Authors:  Yuichi Sato; Kenjiro Kimura; Tatsuya Chikaraishi
Journal:  J Artif Organs       Date:  2010-06-05       Impact factor: 1.731

2.  Application of cystatin C reduction ratio to high-flux hemodialysis as an alternative indicator of the clearance of middle molecules.

Authors:  Joon-Sung Park; Gheun-Ho Kim; Chong Myung Kang; Chang Hwa Lee
Journal:  Korean J Intern Med       Date:  2010-02-26       Impact factor: 3.165

3.  Finite volume scheme for double convection-diffusion exchange of solutes in bicarbonate high-flux hollow-fiber dialyzer therapy.

Authors:  Kodwo Annan
Journal:  Comput Math Methods Med       Date:  2012-10-31       Impact factor: 2.238

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.