Literature DB >> 11981152

Effect of epidural epinephrine on the minimum local analgesic concentration of epidural bupivacaine in labor.

Linda S Polley1, Malachy O Columb, Norah N Naughton, Deborah S Wagner, Cosmas J M van de Ven.   

Abstract

BACKGROUND: The minimum local analgesic concentration (MLAC) has been defined as the median effective local analgesic concentration in a 20-ml volume for epidural analgesia in the first stage of labor. The aim of this study was to determine the local anesthetic-sparing efficacy of epidural epinephrine by its effect on the MLAC of bupivacaine.
METHODS: In this double-blind, randomized, prospective study, 70 parturients who were at 7 cm or less cervical dilation and who requested epidural analgesia were allocated to one of two groups. After lumbar epidural catheter placement, 20 ml bupivacaine (n = 35) or bupivacaine with epinephrine 1:300,000 (n = 35) was administered. The concentration of bupivacaine was determined by the response of the previous patient in that group to a higher or lower concentration using up-down sequential allocation. Analgesic efficacy was assessed using 100-mm visual analog pain scores, with 10 mm or less within 30 min defined as effective.
RESULTS: The MLAC of bupivacaine alone was 0.091% wt/vol (95% confidence interval, 0.081-0.102). The addition of epinephrine 1:300,000 (66.7 microg) resulted in a significant reduction (P < 0.01) in the MLAC of bupivacaine to 0.065% wt/vol (95% confidence interval, 0.047-0.083). The lowest maternal blood pressure was significantly lower in the bupivacaine-epinephrine group (P = 0.03). There were statistically significant reductions in fetal heart rate (P = 0.011) in the bupivacaine-epinephrine group that were not clinically significant.
CONCLUSIONS: The addition of epidural epinephrine 1:300,000 (66 microg) resulted in a significant 29% reduction in the MLAC of bupivacaine. Coincident reductions in fetal heart rate and maternal blood pressure were also observed that were not clinically significant.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11981152     DOI: 10.1097/00000542-200205000-00015

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  4 in total

1.  Evaluation of association factors for labor episodic pain during epidural analgesia.

Authors:  Jason Ju In Chan; Yuan Ying Gan; Rajive Dabas; Nian-Lin Reena Han; Rehena Sultana; Alex Tiong Heng Sia; Ban Leong Sng
Journal:  J Pain Res       Date:  2019-02-15       Impact factor: 3.133

2.  Labor Analgesia in Brugada Syndrome and the Importance of Contingency Planning.

Authors:  Shayla Mena; Ana Costa; Michelle DeLemos; Joy Schabel; Morgane Factor
Journal:  Case Rep Anesthesiol       Date:  2022-07-15

3.  Extracts from rabbit skin inflamed by the vaccinia virus attenuate bupivacaine-induced spinal neurotoxicity in pregnant rats.

Authors:  Rui Cui; Shiyuan Xu; Liang Wang; Hongyi Lei; Qingxiang Cai; Hongfei Zhang; Dongmei Wang
Journal:  Neural Regen Res       Date:  2013-04-15       Impact factor: 5.135

4.  Effects of different sufentanil target concentrations on the MACBAR of sevoflurane in patients with carbon dioxide pneumoperitoneum stimulus.

Authors:  Yanxia Guo; Dan Wang; Xiaolin Yang; Pingping Jiang; Juan Xu; Guoyuan Zhang
Journal:  BMC Anesthesiol       Date:  2020-09-21       Impact factor: 2.217

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.