Literature DB >> 11981151

Utility of whole blood hemostatometry using the clot signature analyzer for assessment of hemostasis in cardiac surgery.

Nauder Faraday1, Eliseo Guallar, Valerie A Sera, Everlie D Bolton, Robert B Scharpf, Ann M Cartarius, Kathryn Emery, Julia Concord, Thomas S Kickler.   

Abstract

BACKGROUND: A hemostatic monitor capable of rapid, accurate detection of clinical coagulopathy within the operating room could improve management of bleeding after cardiopulmonary bypass (CPB). The Clot Signature Analyzer is a hemostatometer that measures global hemostasis in whole blood. The authors hypothesized that point-of-care hemostatometry could detect a clinical coagulopathic state in cardiac surgical patients.
METHODS: Fifty-seven adult patients scheduled for a variety of elective cardiac surgical procedures were studied. Anesthesia, CPB, heparin anticoagulation, protamine reversal, and transfusion for post-CPB bleeding were all managed by standardized protocol. Clinical coagulopathy was defined by the need for platelet or fresh frozen plasma transfusion. The Clot Signature Analyzer collagen-induced thrombus formation (CITF) assay measured platelet-mediated hemostasis in vitro. The activated clotting time, platelet count, prothrombin time, activated partial thromboplastin time, and fibrinogen concentration were also measured.
RESULTS: The postprotamine CITF was greater in patients who required hemostatic transfusion than in those who did not (17.6 +/- 8.0 min vs. 10.5 +/- 5.7 min, respectively; P < 0.01). Postprotamine CITF values were highly correlated with platelet and fresh frozen plasma transfusion (Spearman r = 0.50, P < 0.001 and r = 0.40, P < 0.005, respectively). Receiver operator characteristic curves showed a highly significant relation between the postprotamine CITF and intraoperative platelet and fresh frozen plasma transfusion (area under the curve, 0.78-0.81, P < 0.005) with 60-80% sensitivity, specificity, positive and negative predictive values at cutoffs of 12-14 min. Logistic regression demonstrated that the CITF was independently predictive of post-CPB hemostatic transfusion, but standard hemostatic assays were not.
CONCLUSIONS: The Clot Signature Analyzer CITF detects a clinical coagulopathic state after CPB and is independently predictive of the need for hemostatic transfusion. Hemostatometry has potential utility for monitoring hemostasis in cardiac surgery.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11981151     DOI: 10.1097/00000542-200205000-00014

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  1 in total

Review 1.  The effects of pre- and postoperative fibrinogen levels on blood loss after cardiac surgery: a systematic review and meta-analysis.

Authors:  Chantal Gielen; Olaf Dekkers; Theo Stijnen; Jan Schoones; Anneke Brand; Robert Klautz; Jeroen Eikenboom
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-12-06
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.