Literature DB >> 11973089

Speed of capsular bend formation at the optic edge of acrylic, silicone, and poly(methyl methacrylate) lenses.

Okihiro Nishi1, Kayo Nishi, Junsuke Akura.   

Abstract

PURPOSE: To evaluate how and how fast a capsular bend is created clinically at the optic edge of an intraocular lens (IOL) after cataract surgery.
SETTING: Jinshikai Medical Foundation, Nishi Eye Hospital, Osaka, Japan.
METHODS: Capsular bend formation was observed by slitlamp after maximum pupil dilation in 45 eyes of 45 patients with senile cataract. Fifteen eyes each received an AcrySof MA60BM acrylic (Alcon), PhacoFlex II SI-40NB silicone (Allergan), or UV26T poly(methyl methacrylate) (PMMA) (Menicon) IOL. Patients were evaluated prospectively at 1 day and 1, 2, and 4 weeks and retrospectively (15 eyes per IOL) 1 year after cataract surgery. A capsular bend index was developed to document and categorize the capsular bend formation process at the IOL optic edge.
RESULTS: The anterior and posterior capsules adhered, with the latter attracted to the former. The adhesion always progressed from the periphery to the optic edge so that the posterior capsule eventually wrapped around the posterior optic edge, although not fully circumferentially in all cases. The process took place in 4 stages. Capsular bend formation was complete 1 month after surgery with the foldable IOLs (AcrySof, PhacoFlex II) but was significantly delayed with the PMMA IOL. After 1 year, the capsular wrapping was firm and fully circumferential at the optic edge with all IOL types in all cases.
CONCLUSIONS: Capsular bend formation progressed in the same fashion but at significantly different speeds among the IOLs, suggesting that the process depends on IOL material and design. Fast, early capsular bend formation may be 1 reason AcrySof and PhacoFlex II IOLs prevent PCO statistically better than PMMA IOLs. The results indicate that PCO is prevented by the sharp capsular bend created by sharp optic edges and by quick bend formation.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11973089     DOI: 10.1016/s0886-3350(01)01094-x

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  19 in total

1.  Posterior capsule opacification after implantation of a hydrogel intraocular lens.

Authors:  K Hayashi; H Hayashi
Journal:  Br J Ophthalmol       Date:  2004-02       Impact factor: 4.638

2.  Single versus three piece acrylic IOLs.

Authors:  D F Chang
Journal:  Br J Ophthalmol       Date:  2004-06       Impact factor: 4.638

3.  [Influence of intraocular lens material and design on the development of posterior capsule opacification].

Authors:  O Nishi
Journal:  Ophthalmologe       Date:  2005-06       Impact factor: 1.059

4.  Nd:YAG capsulotomy rates after use of the AcrySof acrylic three piece and one piece intraocular lenses.

Authors:  S I Mian; K Fahim; A Marcovitch; H Gada; D C Musch; A Sugar
Journal:  Br J Ophthalmol       Date:  2005-11       Impact factor: 4.638

5.  Corrective Techniques and Future Directions for Treatment of Residual Refractive Error Following Cataract Surgery.

Authors:  Majid Moshirfar; Michael V McCaughey; Luis Santiago-Caban
Journal:  Expert Rev Ophthalmol       Date:  2014-12

6.  Effect of delivery of MMP inhibitors from PDMS as a model IOL material on PCO markers.

Authors:  Diana Morarescu; Judy A West-Mays; Heather D Sheardown
Journal:  Biomaterials       Date:  2009-12-22       Impact factor: 12.479

7.  Posterior capsule opacification following 20- and 23-gauge phacovitrectomy (posterior capsule opacification following phacovitrectomy).

Authors:  T Iwase; B C Oveson; Y Nishi
Journal:  Eye (Lond)       Date:  2012-09-28       Impact factor: 3.775

8.  Ablation of lens epithelial cells with a laser photolysis system: histopathology, ultrastructure, and immunochemistry.

Authors:  Nick Mamalis; Hans E Grossniklaus; George O Waring; Liliana Werner; Jacob Brubaker; Don Davis; Ladan Espandar; Rudolf Walker; Reinhardt Thyzel
Journal:  J Cataract Refract Surg       Date:  2010-06       Impact factor: 3.351

9.  Findings of an experimental study in a rabbit model on posterior capsule opacification after implantation of hydrophobic acrylic and hydrophilic acrylic intraocular lenses.

Authors:  Nikolaos Trakos; Elli Ioachim; Elena Tsanou; Miltiadis Aspiotis; Konstantinos Psilas; Chris Kalogeropoulos
Journal:  Clin Ophthalmol       Date:  2008-12

10.  Adherence and viability of porcine lens epithelial cells on three different IOL materials in vitro.

Authors:  Yvonne Hesse; Jürgen Kampmeier; Gerhard K Lang; Alicia Baldysiak-Figiel; Gabriele E Lang
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2003-08-23       Impact factor: 3.117

View more