Failure of fixation of tibial plateau fractures.

Ahmad M Ali1, M El-Shafie, K M Willett.   

Abstract

OBJECTIVE: To define the failure of fixation in tibial plateau fractures, detect its incidence, and determine the contributing factors.
DESIGN: Mail survey and literature review were used to define the fixation failure; this definition was applied to a radiologic review of patients who were treated surgically for tibial plateau fracture at a Level 1 trauma unit for a three-year period from 1993 to 1995. PATIENTS AND
SETTING: Forty-two consecutive patients treated surgically at our trauma unit for tibial plateau fractures were studied retrospectively, specifically for loss of fixation. Factors that might affect the fracture fixation were reviewed, including age, mechanism of injury, type of fracture, bone quality, severity of fragmentation, severity of displacement, time to surgery, operating time, fixation method, use of bone graft, postoperative bracing, and mobilization. MAIN OUTCOME MEASURES: The main outcome measure was failure of fixation, by using criteria defined by the result of a mail survey of experts and literature review.
RESULTS: Using a strict definition of radiologic failure of fixation, we reported an overall 31 percent rate of failure of fixation: 79 percent in patients older than sixty years compared with 7 percent in younger patients. The statistically significant associations with loss of reduction were age more than sixty years, premature weight bearing, preoperative displacement, fracture fragmentation, and severe osteoporosis.
CONCLUSION: It is logical to define failure of fixation using the same measures considered as indications for reduction and fixation. Using these strict criteria, the incidence of radiologic failure was much higher than previous published series. In the elderly this was unacceptably high, and treatment goals should be limited to restoring stability and alignment.

Entities:  

Mesh:

Year:  2002        PMID: 11972075     DOI: 10.1097/00005131-200205000-00006

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  27 in total

Review 1.  Surgical treatment options in patients with impaired bone quality.

Authors:  Norman A Johanson; Jody Litrenta; Jay M Zampini; Frederic Kleinbart; Haviva M Goldman
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

2.  Post-operative complications of tibial plateau fractures treated with screws or hybrid external fixation.

Authors:  F Stefanelli; I Cucurnia; A Grassi; N Pizza; S Di Paolo; M Casali; F Raggi; M Romagnoli; S Zaffagnini
Journal:  Musculoskelet Surg       Date:  2021-08-03

3.  Knee joint replacement as primary treatment for proximal tibial fractures: analysis of clinical results of twenty-two patients with mean follow-up of nineteen months.

Authors:  Valtteri Tapper; Alar Toom; Maija Pesola; Konsta Pamilo; Juha Paloneva
Journal:  Int Orthop       Date:  2019-10-23       Impact factor: 3.075

4.  Comparison of traditional surgery and surgery assisted by three dimensional printing technology in the treatment of tibial plateau fractures.

Authors:  Yiting Lou; Leyi Cai; Chenggui Wang; Qian Tang; Tianlong Pan; Xiaoshan Guo; Jianshun Wang
Journal:  Int Orthop       Date:  2017-04-10       Impact factor: 3.075

5.  Two-level fixation with headless compression screws for tibial plateau fractures.

Authors:  Robert Kaspar Wagner; Peter Kloen
Journal:  Eur J Trauma Emerg Surg       Date:  2022-05-14       Impact factor: 3.693

6.  Effects of combined therapy of alendronate and low-intensity pulsed ultrasound on metaphyseal bone repair after osteotomy in the proximal tibia of aged rats.

Authors:  Hiroshi Aonuma; Naohisa Miyakoshi; Yuji Kasukawa; Keiji Kamo; Hiroshi Sasaki; Hiroyuki Tsuchie; Toyohito Segawa; Yoichi Shimada
Journal:  J Bone Miner Metab       Date:  2013-08-07       Impact factor: 2.626

7.  Angle Stable Interlocking Intramedullary Nails for Tibial Plateau Fractures.

Authors:  Peng Jia; Feng-Cheng Lu; Kifayat Ullah; Man Zhang; Yan-Sheng Dong; Chao Xiong; Zhi-Hui Zhao; Jin-Feng Wang; Ju-Wen Chen; Yong-Qing Wang
Journal:  Orthop Surg       Date:  2018-05-16       Impact factor: 2.071

8.  Settable polymer/ceramic composite bone grafts stabilize weight-bearing tibial plateau slot defects and integrate with host bone in an ovine model.

Authors:  Sichang Lu; Madison A P McGough; Stefanie M Shiels; Katarzyna J Zienkiewicz; Alyssa R Merkel; Joseph P Vanderburgh; Jeffry S Nyman; Julie A Sterling; David J Tennent; Joseph C Wenke; Scott A Guelcher
Journal:  Biomaterials       Date:  2018-06-26       Impact factor: 12.479

9.  Can low intensity pulsed ultrasound (LIPUS) be used as an alternative to revision surgery for patients with non-unions following fracture fixation?

Authors:  Vidhi Adukia; Zahra Al-Hubeshy; Jitendra Mangwani
Journal:  J Clin Orthop Trauma       Date:  2020-11-21

10.  Unilateral locking plate versus unilateral locking plate combined with compression bolt for Schatzker I-IV tibial plateau fractures: a comparative study.

Authors:  Zhongzheng Wang; Zhanle Zheng; Yuchuan Wang; Yanbin Zhu; Zhanchao Tan; Wei Chen; Zhiyong Hou; Yingze Zhang
Journal:  Int Orthop       Date:  2022-02-02       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.