Literature DB >> 11967133

The United Kingdom National External Quality Assessment Scheme (blood transfusion laboratory practice): trends in proficiency and practice between 1985 and 2000.

S M Knowles1, C E Milkins, J F Chapman, M Scott.   

Abstract

Proficiency in blood transfusion laboratory practice has improved over the last 15 years (1985-2000). Error rates for ABO grouping have fallen from 0 x 19 to 0 x 02% (P = 0 x 003). A similar trend is evident for antibody screening, with error rates for false negative antibody screens falling from 3 x 2 to 0 x 5% (P < 0 x 001), and for antibody identification, for sera containing a single alloantibody, with error rates falling from 8 x 8% to 0 x 9% over the last 10 years (P < 0 x 001). Proficiency in serological crossmatching to detect clinically significant non-ABO incompatibilities (other than Kidd), has also improved (P < 0 x 001). However, error rates for RhD grouping have not changed and there has been a recent decline in proficiency in detecting weak ABO incompatibilities and Kidd antibodies with heterozygous cells. Procedures for pretransfusion testing have also been rationalized over this time. The indirect antiglobulin test (IAT) is used in isolation by 73% of laboratories for antibody screening, and 10% rely on the direct room temperature (DRT), immediate spin (IS) crossmatch in the absence (current and/or historical) of clinically significant antibodies. Despite the improvements in error rates that have occurred alongside the rationalizations, there is still evidence of noncompliance with current published BCSH guidelines and manufacturers' instructions.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11967133     DOI: 10.1046/j.1365-3148.2002.00353.x

Source DB:  PubMed          Journal:  Transfus Med        ISSN: 0958-7578            Impact factor:   2.019


  4 in total

1.  Twelve years of the Brazilian External Quality Assessment Program in Immunohematology: benefits of the program.

Authors:  Laércio Melo; Jordão Pellegrino; Celso Bianco; Lilian Castilho
Journal:  J Clin Lab Anal       Date:  2005       Impact factor: 2.352

2.  Role of enzyme-treated cells in RBC antibody screening using the gel test: a study of anti-RH1, -RH2, and -RH3 antibodies.

Authors:  Jocelyne Conne; Philippe Schneider; Jean-Daniel Tissot
Journal:  J Clin Lab Anal       Date:  2007       Impact factor: 2.352

3.  Performance Assessment of Internal Quality Control (IQC) Products in Blood Transfusion Compatibility Testing in China.

Authors:  Gui-Ping Xu; Li-Fang Wu; Jing-Jing Li; Qi Gao; Zhi-Dong Liu; Qiong-Hua Kang; Yi-Jun Hou; Luo-Chuan Zhang; Xiao-Mei Hu; Jie Li; Juan Zhang
Journal:  PLoS One       Date:  2015-10-21       Impact factor: 3.240

4.  A comparison of three column agglutination tests for red blood cell alloantibody identification.

Authors:  Siska Blomme; Emilie De Maertelaere; Eline Verhoye
Journal:  BMC Res Notes       Date:  2020-03-04