Literature DB >> 11966313

Photomechanical investigations on post endodontically rehabilitated teeth.

A Kishen1, A Asundi.   

Abstract

An investigation of the stress distribution patterns in post-core restored teeth and the behavior of dentin material to fracture propagation was conducted using experimental techniques such as digital photoelasticity (on photoelastic models), mechanical testing and scanning electron microscopy (SEM) (on extracted teeth). Digital photoelastic experiments showed that endodontic post-core restoration resulted in regions of high tensile stress and of stress concentrations in the remaining dentin structure. It was observed from mechanical testing that the fracture resistance in post-core restored teeth is significantly lower (p<0.0001) than that in intact tooth. There was a significant correspondence between the plane of stress concentrations identified in the photoelastic models and in those of the plane of fracture exhibited by the rehabilitated tooth specimens. While the fracture of post-core rehabilitated teeth was consistent, that of control teeth was not as distinct. The SEM highlighted varying dentin response to fracture propagation at the inner core and the outer regions. The fractographs showed brittle and ductile response to fracture propagation in the outer and inner core dentin, respectively. These photomechanical studies highlighted that the stress concentrations, high tensile stress and loss of inner ductile dentin associated with post endodontic rehabilitation diminished their resistance to fracture.

Entities:  

Mesh:

Year:  2002        PMID: 11966313     DOI: 10.1117/1.1463046

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  8 in total

1.  Biomechanical validation of an artificial tooth-periodontal ligament-bone complex for in vitro orthodontic load measurement.

Authors:  Zeyang Xia; Jie Chen
Journal:  Angle Orthod       Date:  2012-09-12       Impact factor: 2.079

2.  Finite element analysis of stress concentration in three popular brands of fiber posts systems used for maxillary central incisor teeth.

Authors:  Shalini Aggarwal; Vaibhav Garg
Journal:  J Conserv Dent       Date:  2011-07

3.  Stress distribution of endodontically treated teeth with titanium alloy post and carbon fiber post with different alveolar bone height: A three-dimensional finite element analysis.

Authors:  S Vijay Singh; Manohar Bhat; Saurabh Gupta; Deepak Sharma; Harsha Satija; Sumeet Sharma
Journal:  Eur J Dent       Date:  2015 Jul-Sep

4.  Theoretical Design of Multilayer Dental Posts Using CAD-Based Approach and Sol-Gel Chemistry.

Authors:  Saverio Maietta; Roberto De Santis; Michelina Catauro; Massimo Martorelli; Antonio Gloria
Journal:  Materials (Basel)       Date:  2018-05-07       Impact factor: 3.623

5.  Effect of Hand and Rotary Instruments on the Fracture Resistance of Teeth: An In Vitro Study.

Authors:  Nisha Acharya; Md Riasat Hasan; Dashrath Kafle; Anil Chakradhar; Takashi Saito
Journal:  Dent J (Basel)       Date:  2020-04-29

6.  Analysis of clinical associated factors of vertical root fracture cases found in endodontic surgery.

Authors:  Li-Ting Hsiao; Jung-Chun Ho; Chiung-Fang Huang; Wei-Chiang Hung; Chun-Wei Chang
Journal:  J Dent Sci       Date:  2019-10-23       Impact factor: 2.080

7.  Comparison of stresses induced by fiber post, parapost and casting post in root canals by photoelasticity method.

Authors:  Aliakbar Rezaei; Fereidoon Soltani; Fariborz Vafaei; Masoumeh Khoshhal; Majid Reza Ayatollahi; Naser Soltani; Morteza Nejati
Journal:  Iran Endod J       Date:  2010-02-20

8.  The Effect of Intraradicular Multiple Fiber and Cast Posts on the Fracture Resistance of Endodontically Treated Teeth with Wide Root Canals.

Authors:  Satheesh B Haralur; Maram Awdah Al Ahmari; Safeyah Abdurrahman AlQarni; Mashael Khaled Althobati
Journal:  Biomed Res Int       Date:  2018-08-15       Impact factor: 3.411

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.