Literature DB >> 11959471

Enhancement of operational stability of an enzyme biosensor for glucose and sucrose using protein based stabilizing agents.

M D Gouda1, M A Kumar, M S Thakur, N G Karanth.   

Abstract

With the incorporation of lysozyme during the immobilization step, considerable enhancement of the operational stability of a biosensor has been demonstrated in the case of an immobilized single enzyme (glucose oxidase) system for glucose and multienzyme (invertase, mutarotase and glucose oxidase) system for sucrose. Thus an increased number of repeated analyses of 750 samples during 230 days for glucose and 400 samples during 40 days of operation for sucrose have been achieved. The increased operational stability of immobilized single and multienzyme system, will improve the operating cost effectiveness of the biosensor.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11959471     DOI: 10.1016/s0956-5663(02)00021-0

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  14 in total

1.  Comparative assessment of tea quality by various analytical and sensory methods with emphasis on tea polyphenols.

Authors:  P V Sujith Kumar; Shabana Basheer; R Ravi; M S Thakur
Journal:  J Food Sci Technol       Date:  2011-02-22       Impact factor: 2.701

2.  Phenylalanine Monitoring via Aptamer-Field-Effect Transistor Sensors.

Authors:  Kevin M Cheung; Kyung-Ae Yang; Nako Nakatsuka; Chuanzhen Zhao; Mao Ye; Michael E Jung; Hongyan Yang; Paul S Weiss; Milan N Stojanović; Anne M Andrews
Journal:  ACS Sens       Date:  2019-11-01       Impact factor: 7.711

3.  β-Hydroxybutyrate dehydrogenase decorated MXene nanosheets for the amperometric determination of β-hydroxybutyrate.

Authors:  Aneesh Koyappayil; Sachin Ganpat Chavan; Mohsen Mohammadniaei; Anna Go; Sei Young Hwang; Min-Ho Lee
Journal:  Mikrochim Acta       Date:  2020-04-20       Impact factor: 5.833

4.  A high-throughput enzyme assay for organophosphate residues in milk.

Authors:  Rupesh K Mishra; Kanchanmala Deshpande; Sunil Bhand
Journal:  Sensors (Basel)       Date:  2010-12-09       Impact factor: 3.576

5.  A biosensor for urea from succinimide-modified acrylic microspheres based on reflectance transduction.

Authors:  Alizar Ulianas; Lee Yook Heng; Musa Ahmad
Journal:  Sensors (Basel)       Date:  2011-08-26       Impact factor: 3.576

6.  The detection of alkaline phosphatase using an electrochemical biosensor in a single-step approach.

Authors:  Joanne H Wang; Kevin Wang; Brandon Bartling; Chung-Chiun Liu
Journal:  Sensors (Basel)       Date:  2009-10-30       Impact factor: 3.576

7.  Studies on enhancing operational stability of a reusable laccase-based biosensor probe for detection of ortho-substituted phenolic derivatives.

Authors:  C Sarika; K Rekha; B Narasimha Murthy
Journal:  3 Biotech       Date:  2015-03-10       Impact factor: 2.406

Review 8.  Enzyme Biosensors for Biomedical Applications: Strategies for Safeguarding Analytical Performances in Biological Fluids.

Authors:  Gaia Rocchitta; Angela Spanu; Sergio Babudieri; Gavinella Latte; Giordano Madeddu; Grazia Galleri; Susanna Nuvoli; Paola Bagella; Maria Ilaria Demartis; Vito Fiore; Roberto Manetti; Pier Andrea Serra
Journal:  Sensors (Basel)       Date:  2016-05-30       Impact factor: 3.576

9.  Non-complexed four cascade enzyme mixture: simple purification and synergetic co-stabilization.

Authors:  Suwan Myung; Y-H Percival Zhang
Journal:  PLoS One       Date:  2013-04-09       Impact factor: 3.240

10.  A large response range reflectometric urea biosensor made from silica-gel nanoparticles.

Authors:  Muawia Alqasaimeh; Lee Yook Heng; Musa Ahmad; A S Santhana Raj; Tan Ling Ling
Journal:  Sensors (Basel)       Date:  2014-07-22       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.