Literature DB >> 11956919

Lumbar lateral interbody cage with plate augmentation: in vitro biomechanical analysis.

J C Le Huec1, M Liu, W Skalli, L Josse.   

Abstract

Many studies have concluded that stand alone cages provide limited stabilization to the spine, and this primary stabilization decreases postoperatively due to various factors. A supplemental fixation may, therefore, be needed to improve the stability. Extensive biomechanical analysis was performed in the present study to further evaluate the stabilization achieved by a laterally inserted cage and the role of an anterior lateral supplemental fixation. Eight human cadaver functional spinal units were subjected sequentially to four different test conditions: (1) intact, (2) instrumented laterally with a long cylindrical threaded cage, (3) the same cage supplemented with a lateral fixation plate, the plate being firmly connected to the cage, and (4) removal of the connection between the plate and the cage. Pure moments were applied to each specimen in a quasi static manner, ranging from -7 Nm to 7 Nm in flexion/extension, lateral bending and axial rotation. Three-dimensional segmental motions were simultaneously recorded under each loading condition. Statistical analysis was carried out on the motion parameters, including the range of motion (ROM) and the neutral zone (NZ). Inter-group comparisons were made using the Friedman test and the Wilcoxon test. The results showed that the stand alone lateral cage provided stabilization by increasing segmental stiffness above that of the intact spine. The stiffness increase ratios were: 1.6 in flexion/extension ( P=0.07), 1.3 in lateral bending ( P=0.4) and 1.0 in axial rotation ( P=0.67). A supplemental plate provided significant reinforcement of the stabilization. The stiffness increase ratios relative to the intact spine were: 3.1 in flexion/extension ( P=0.012), 5.0 in lateral bending ( P=0.012) and 2.3 in axial rotation ( P=0.012). After removal of the connection between the cage and the plate, the stiffness ratios were: 2.7 in flexion/extension ( P=0.027), 4.6 in lateral bending ( P=0.027) and 2.1 in axial rotation ( P=0.027). Globally, the cage alone increased the segmental stiffness above that of the intact spine by a factor of 1.1 ( P=0.39), with the supplemental plate, segmental stiffness increased by a factor of 3.1 ( P<0.01), and the unconnected cage/plate increased stiffness by a factor of 3.0 ( P=0.02). Supplementation of the lateral cage with an anterolateral plate was thus shown to provide significant additional stabilization in all directions, which may potentially compensate for the postoperative decrease in segmental stability.

Entities:  

Mesh:

Year:  2001        PMID: 11956919      PMCID: PMC3610508          DOI: 10.1007/s005860100316

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  6 in total

1.  Comparison of conventional versus minimally invasive extraperitoneal approach for anterior lumbar interbody fusion.

Authors:  V Saraph; C Lerch; N Walochnik; C M Bach; M Krismer; C Wimmer
Journal:  Eur Spine J       Date:  2004-05-08       Impact factor: 3.134

2.  Biomechanical comparison of two different concepts for stand alone anterior lumbar interbody fusion.

Authors:  Philipp Schleicher; R Gerlach; B Schär; C M J Cain; W Achatz; R Pflugmacher; N P Haas; F Kandziora
Journal:  Eur Spine J       Date:  2008-10-08       Impact factor: 3.134

3.  Thoracoscopic anterior stabilization for thoracolumbar fractures in patients without spinal cord injury: quality of life and long-term results.

Authors:  Arjen J Smits; Arwin Noor; Fred C Bakker; Jaap Deunk; Frank W Bloemers
Journal:  Eur Spine J       Date:  2018-04-03       Impact factor: 3.134

4.  Early clinical and radiological results of unilateral posterior pedicle instrumentation through a Wiltse approach with lateral lumbar interbody fusion.

Authors:  Jerry Y Du; Paul D Kiely; Eric Bogner; Motasem Al Maaieh; Alexander Aichmair; Stephan N Salzmann; Russel C Huang
Journal:  J Spine Surg       Date:  2017-09

5.  Biomechanical evaluation of a biomimetic spinal construct.

Authors:  Tian Wang; Jonathon R Ball; Mattew H Pelletier; William R Walsh
Journal:  J Exp Orthop       Date:  2014-06-26

6.  Biomechanics of lateral interbody spacers: going wider for going stiffer.

Authors:  Luiz Pimenta; Alexander W L Turner; Zachary A Dooley; Rachit D Parikh; Mark D Peterson
Journal:  ScientificWorldJournal       Date:  2012-11-13
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.