Literature DB >> 11955847

Efficacy and safety of percutaneous treatment of iatrogenic femoral artery pseudoaneurysm by biodegradable collagen injection.

Karim Hamraoui1, Sjef M P G Ernst, Pascal F H M van Dessel, Johannes C Kelder, Jurriën M ten Berg, Maarten Jan Suttorp, Wybren Jaarsma, Thijs H W Plokker.   

Abstract

UNLABELLED: OBJECTIVES; The goal of this study was to assess the safety and efficacy of femoral artery pseudoaneurysm (FAP) closure by collagen injection. BACKGROUND; The FAP is an infrequent but troublesome complication after percutaneous transfemoral catheter procedures. If ultrasound-guided compression repair (UGCR) fails, vascular surgery is indicated. We have developed a less invasive method to close FAPs percutaneously by injecting collagen and, thus, inducing clotting within the aneurysm.
METHODS: Via a 9F needle or 11F sheath, a biodegradable adhesive bovine collagen is injected percutaneously into the FAP, guided by angiography from the contralateral site.
RESULTS: From 1993 to 2000, compression and UGCR had failed to obliterate 110 FAPs. These patients have been treated by collagen injection. Mean age of the patients was 65.6 +/- 10.2 years (range: 32 to 85 years), and 50% were women. Immediate closure of the FAP was achieved in 107/110 patients (97.3%) without any complication or adverse effect. In one patient the collagen could not be applied due to unfavorable anatomy. One patient needed a second session of collagen injection. In one patient too much collagen was inserted, which resulted in external compression of the artery, and surgical intervention was required. The overall success rate was 108/110 (98%, 95% confidence interval: 93.5% to 99.8%). Among the patients with successful procedures, there were no recurrences during six months follow-up.
CONCLUSIONS: The percutaneous treatment of iatrogenic FAP, by injection with collagen, is an effective and safe strategy. This method provides an excellent therapeutic alternative to the traditional surgical management.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11955847     DOI: 10.1016/s0735-1097(02)01752-7

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  7 in total

1.  Characteristics of Pseudoaneurysms in Northern India; Risk Analysis, Clinical Profile, Surgical Management and Outcome.

Authors:  Hafeezulla Lone; Farooq Ahmad Ganaie; Ghulam Nabi Lone; Abdul Majeed Dar; Mohammad Akbar Bhat; Shyam Singh; Khursheed Ahmad Parra
Journal:  Bull Emerg Trauma       Date:  2015-04

2.  Iatrogenic Femoral Artery Pseudoaneurysm.

Authors:  Bryan T. Piedad; Itzhak Kronzon
Journal:  Curr Treat Options Cardiovasc Med       Date:  2003-04

Review 3.  Iatrogenic pseudoaneurysm of femoral artery: case report and literature review.

Authors:  Martina Lenartova; Tahir Tak
Journal:  Clin Med Res       Date:  2003-07

4.  A novel approach for reducing ischemic mitral regurgitation by injection of a polymer to reverse remodel and reposition displaced papillary muscles.

Authors:  Judy Hung; Jorge Solis; J Luis Guerrero; Gavin J C Braithwaite; Orhun K Muratoglu; Miguel Chaput; Leticia Fernandez-Friera; Mark D Handschumacher; Van J Wedeen; Stuart Houser; Gus J Vlahakes; Robert A Levine
Journal:  Circulation       Date:  2008-09-30       Impact factor: 29.690

5.  Vascular complications and special problems in vascular trauma.

Authors:  M J Martin; A J Perez-Alonso; J A Asensio
Journal:  Eur J Trauma Emerg Surg       Date:  2013-10-23       Impact factor: 3.693

6.  Late to early velocity index as a predictor of iatrogenic femoral artery pseudoaneurysm recurrence in patients treated with ultrasound-guided thrombin injection.

Authors:  Jacek Kurzawski; Agnieszka Janion-Sadowska; Łukasz Zandecki; Marianna Janion; Marcin Sadowski
Journal:  Arch Med Sci       Date:  2019-05-21       Impact factor: 3.318

7.  Endovascular management of posttraumatic and iatrogenic large pelvic pseudoaneurysms following biopsy: case report.

Authors:  Win Phyu; Taryar Zaw; Jonathan K Park; Megan Chang; Hsin-Yi Lee
Journal:  Radiol Case Rep       Date:  2016-12-26
  7 in total