New criteria for estimating baroreflex sensitivity using the transfer function method.

G D Pinna1, R Maestri.   

Abstract

Computer simulations were carried out to appraise three new criteria for the estimation of baroreflex sensitivity (BRS) using the transfer function method. The major goal was to identify a computation procedure able to overcome the intrinsic limitations of the classical coherence criterion. Four representative shapes of the gain function and three different average gains (2, 5 and 8 ms(mmHg)(-1) in the low-frequency (LF) band (0.04-0.15Hz) were considered. The signal-to-noise ratio was made to vary so that the peak coherence in the LF band changed from 0.15 to 0.9. All simulation parameters were derived from previous observations in healthy subjects and heart disease patients. The error of the estimated gain function was obtained from its confidence interval. BRS was computed as average gain in the LF band: (a) including in the average only those points having error < or = threshold (criterion 1, C1); (b) calculating the mean error in the band and accepting BRS measurements only when this error was < or = threshold (criterion 2, C2); (c) including in the average all points, regardless of the error (criterion 3, C3). The three criteria were compared in terms of measurability (percentage of measured BRS) and accuracy (bias and SD of BRS). Using C1 and C2, measurability dropped to 10% when the peak coherence in the LF band decreased, respectively, to 0.18-0.41 and to 0.26-0.53, depending on the shape and strength of the gain. In this condition (lower bound of measurability), worst bias and SD (average gain: 8 ms(mmHg)(-1)) were, respectively, 0.8 ms(mmHg)(-1) and 3.3ms(mmHg)(-1) (C1), and 0.1 ms(mmHg)(-1) and 1.0 ms(mmHg)(-1) (C2). C3, by definition, always ensured 100% measurability and showed bias and SD comparable with, or even lower than, C1 and C2, within the common range of measurable BRS. In the extreme condition of 0.15 coherence, bias and SD were, respectively, 1.7 ms(mmHg)(-1) and 2.3ms(mmHg)(-1) (average gain: 8ms(mmHg)(-1)). Hence, error checking (C1 and C2) dramatically reduced measurability and did not improve accuracy of BRS measurements compared with performing no error check (C3). In conditions of low signal-to-noise ratio and/or impaired baroreflex gain, leading to markedly reduced coherence, the simple average of the gain function in the LF band allows BRS to be estimated with accuracy adequate for clinical purposes.

Entities:  

Mesh:

Year:  2002        PMID: 11954712     DOI: 10.1007/bf02347699

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  10 in total

1.  Reliability of transfer function estimates in cardiovascular variability analysis.

Authors:  G D Pinna; R Maestri
Journal:  Med Biol Eng Comput       Date:  2001-05       Impact factor: 2.602

2.  Altered blood pressure variability in patients with congestive heart failure.

Authors:  A Radaelli; S Perlangeli; M C Cerutti; L Mircoli; I Mori; L Boselli; M Bonaita; L Terzoli; G Candotti; G Signorini; A U Ferrari
Journal:  J Hypertens       Date:  1999-12       Impact factor: 4.844

3.  Baroreflex sensitivity and heart-rate variability in prediction of total cardiac mortality after myocardial infarction. ATRAMI (Autonomic Tone and Reflexes After Myocardial Infarction) Investigators.

Authors:  M T La Rovere; J T Bigger; F I Marcus; A Mortara; P J Schwartz
Journal:  Lancet       Date:  1998-02-14       Impact factor: 79.321

4.  Assessment of baroreceptor reflex sensitivity by means of spectral analysis.

Authors:  H W Robbe; L J Mulder; H Rüddel; W A Langewitz; J B Veldman; G Mulder
Journal:  Hypertension       Date:  1987-11       Impact factor: 10.190

5.  Cardiovascular variability signals: towards the identification of a closed-loop model of the neural control mechanisms.

Authors:  G Baselli; S Cerutti; S Civardi; A Malliani; M Pagani
Journal:  IEEE Trans Biomed Eng       Date:  1988-12       Impact factor: 4.538

6.  Depressed arterial baroreflex sensitivity and not reduced heart rate variability identifies patients with chronic heart failure and nonsustained ventricular tachycardia: the effect of high ventricular filling pressure.

Authors:  A Mortara; M T La Rovere; G D Pinna; P Parziale; R Maestri; S Capomolla; C Opasich; F Cobelli; L Tavazzi
Journal:  Am Heart J       Date:  1997-11       Impact factor: 4.749

7.  Hemodynamic fluctuations and baroreflex sensitivity in humans: a beat-to-beat model.

Authors:  R W deBoer; J M Karemaker; J Strackee
Journal:  Am J Physiol       Date:  1987-09

8.  The arterial baroreceptor reflex of the rat exhibits positive feedback properties at the frequency of mayer waves.

Authors:  D Bertram; C Barres; G Cuisinaud; C Julien
Journal:  J Physiol       Date:  1998-11-15       Impact factor: 5.182

9.  Fundamental relations between short-term RR interval and arterial pressure oscillations in humans.

Authors:  J A Taylor; D L Eckberg
Journal:  Circulation       Date:  1996-04-15       Impact factor: 29.690

10.  Physiology and pathophysiology of heart rate and blood pressure variability in humans: is power spectral analysis largely an index of baroreflex gain?

Authors:  P Sleight; M T La Rovere; A Mortara; G Pinna; R Maestri; S Leuzzi; B Bianchini; L Tavazzi; L Bernardi
Journal:  Clin Sci (Lond)       Date:  1995-01       Impact factor: 6.124

  10 in total
  14 in total

1.  The effect of dexmedetomidine on arterial-cardiac baroreflex function assessed by spectral and transfer function analysis.

Authors:  Toru Ehara; Yojiro Ogawa; Jitsu Kato; Ken Aoki; Setsuro Ogawa; Ken-ichi Iwasaki
Journal:  J Anesth       Date:  2012-03-02       Impact factor: 2.078

Review 2.  Baroreflex sensitivity: measurement and clinical implications.

Authors:  Maria Teresa La Rovere; Gian Domenico Pinna; Grzegorz Raczak
Journal:  Ann Noninvasive Electrocardiol       Date:  2008-04       Impact factor: 1.468

3.  Baroreflex control of renal sympathetic nerve activity in early heart failure assessed by the sequence method.

Authors:  Renata Maria Lataro; Luiz Eduardo Virgilio Silva; Carlos Alberto Aguiar Silva; Helio Cesar Salgado; Rubens Fazan
Journal:  J Physiol       Date:  2017-04-07       Impact factor: 5.182

Review 4.  Beneficial effects of physical activity on baroreflex control in the elderly.

Authors:  Maria Teresa La Rovere; Gian Domenico Pinna
Journal:  Ann Noninvasive Electrocardiol       Date:  2014-05-21       Impact factor: 1.468

5.  Causal analysis of short-term cardiovascular variability: state-dependent contribution of feedback and feedforward mechanisms.

Authors:  Michal Javorka; Barbora Czippelova; Zuzana Turianikova; Zuzana Lazarova; Ingrid Tonhajzerova; Luca Faes
Journal:  Med Biol Eng Comput       Date:  2016-04-22       Impact factor: 2.602

6.  Daytime baroreflex sensitivity in patients with primary insomnia.

Authors:  Jan Giso Peter; Martin Glos; Alexander Blau; Thomas Penzel; Gert Baumann; Ingo Fietze
Journal:  Clin Res Cardiol       Date:  2010-11-24       Impact factor: 5.460

7.  Baroreflex gain and vasomotor sympathetic modulation in resistant hypertension.

Authors:  Isabelle Magalhães Guedes Freitas; Leonardo Barbosa de Almeida; Natália Portela Pereira; Pedro Augusto de Carvalho Mira; Rogério Baumgratz de Paula; Daniel Godoy Martinez; Edgar Toschi-Dias; Mateus Camaroti Laterza
Journal:  Clin Auton Res       Date:  2017-04-06       Impact factor: 4.435

8.  Dynamic assessment of baroreflex control of heart rate during induction of propofol anesthesia using a point process method.

Authors:  Zhe Chen; Patrick L Purdon; Grace Harrell; Eric T Pierce; John Walsh; Emery N Brown; Riccardo Barbieri
Journal:  Ann Biomed Eng       Date:  2010-10-13       Impact factor: 3.934

9.  Autonomic nervous system activity measured directly and QT interval variability in normal and pacing-induced tachycardia heart failure dogs.

Authors:  Gianfranco Piccirillo; Damiano Magrì; Masahiro Ogawa; Juan Song; Voon J Chong; Seongwook Han; Boyoung Joung; Eue-Keun Choi; Samuel Hwang; Lan S Chen; Shien-Fong Lin; Peng-Sheng Chen
Journal:  J Am Coll Cardiol       Date:  2009-08-25       Impact factor: 24.094

10.  Chronic baroreflex activation restores spontaneous baroreflex control and variability of heart rate in obesity-induced hypertension.

Authors:  Radu Iliescu; Ionut Tudorancea; Eric D Irwin; Thomas E Lohmeier
Journal:  Am J Physiol Heart Circ Physiol       Date:  2013-08-02       Impact factor: 4.733

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.