Literature DB >> 11953940

Assessing the accuracy of high-resolution X-ray computed tomography of primate trabecular bone by comparisons with histological sections.

Roberto José Fajardo1, T M Ryan, J Kappelman.   

Abstract

Different lines of evidence suggest that trabecular bone architecture contains a functional signal related to an organism's locomotor behavior. An understanding of the interspn>ecific and intraspn>ecific variation in extant nonhuman primate trabecular structure is needed to evaluate its usefulness as a tool to reconstruct the locomotor habits of extinct primates. High-resolution X-ray computed tomography (HRXCT) is a new imaging approach with a resolution in the tens of microns that allows nondestructive access to the internal structure of bony elements. Previous studies indicate that such resolution is necessary to accurately quantify structural parameters of trabecular bone. The primary goal of this study was to test the accuracy of HRXCT by comparing stereological measurements from HRXCT images and histological thin sections of cancellous bone taken from the proximal femur and humerus of baboons. To this end, 11 bone samples were scanned on an HRXCT scanner and then thin-sectioned to reveal the scanned plane. HRXCT images were thresholded using a modified half-maximum height protocol. The stereological measurements included bone volume fraction (BV/TV), trabecular number (Tb.N), bone surface to volume ratio (BS/BV), trabecular thickness (Tb.Th), and trabecular spacing (Tb.Sp). The measurement errors on the HRXCT images were 10.90% for BV/TV, 6.06% for Tb.N, 14.19% for BS/BV, 14.33% for Tb.Th, and 7.09% for Tb.Sp, but none of these measurements were significantly different from the histological standards (alpha = 0.05). A second goal of this study was to examine the influence of thresholding, a necessary step in any morphometric study using computed tomography, on the accuracy of the quantitative morphometry. Threshold values derived from a modified half-maximum height protocol showed that parameters derived from the region of interest (area in which stereological measurements were later taken) produced better reconstructions of the actual bone structure than threshold values derived from more inclusive areas of bone. We conclude that HRXCT can accurately reconstruct the complex architecture of trabecular bone, and that thresholding is a nontrivial step in trabecular bone studies, with even slight changes in the protocol greatly affecting the morphometric data. HRXCT represents a valuable analytical tool that should be of interest to a great many researchers in physical anthropology because it allows nondestructive access to internal morphology, thereby preserving valuable and limited skeletal collections. Copyright 2002 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2002        PMID: 11953940     DOI: 10.1002/ajpa.10086

Source DB:  PubMed          Journal:  Am J Phys Anthropol        ISSN: 0002-9483            Impact factor:   2.868


  20 in total

1.  Enamel thickness in the Middle Miocene great apes Anoiapithecus, Pierolapithecus and Dryopithecus.

Authors:  D M Alba; J Fortuny; S Moyà-Solà
Journal:  Proc Biol Sci       Date:  2010-03-24       Impact factor: 5.349

2.  A three-dimensional microcomputed tomographic study of site-specific variation in trabecular microarchitecture in the human second metacarpal.

Authors:  Richard A Lazenby; Sarah Angus; David M L Cooper; Benedikt Hallgrímsson
Journal:  J Anat       Date:  2008-12       Impact factor: 2.610

3.  Anticipating bipedalism: trabecular organization in the newborn ilium.

Authors:  Craig A Cunningham; Sue M Black
Journal:  J Anat       Date:  2009-06       Impact factor: 2.610

4.  Measurement error in μCT-based three-dimensional geometric morphometrics introduced by surface generation and landmark data acquisition.

Authors:  Karolin Engelkes; Jennice Helfsgott; Jörg U Hammel; Sebastian Büsse; Thomas Kleinteich; André Beerlink; Stanislav N Gorb; Alexander Haas
Journal:  J Anat       Date:  2019-05-07       Impact factor: 2.610

5.  Morphometric measurements and sexual dimorphism of the piriform aperture in adults.

Authors:  Eric Moreddu; Laurent Puymerail; Justin Michel; Michaël Achache; Patrick Dessi; Pascal Adalian
Journal:  Surg Radiol Anat       Date:  2013-04-30       Impact factor: 1.246

6.  Beam hardening artifacts in micro-computed tomography scanning can be reduced by X-ray beam filtration and the resulting images can be used to accurately measure BMD.

Authors:  Jeffrey A Meganck; Kenneth M Kozloff; Michael M Thornton; Stephen M Broski; Steven A Goldstein
Journal:  Bone       Date:  2009-08-06       Impact factor: 4.398

7.  Estimating mineral changes in enamel formation by ashing/BSE and microCT.

Authors:  J E Schmitz; J D Teepe; Y Hu; C E Smith; R J Fajardo; Y-H P Chun
Journal:  J Dent Res       Date:  2014-01-27       Impact factor: 6.116

8.  Comparison of alveolar ridge preservation methods using three-dimensional micro-computed tomographic analysis and two-dimensional histometric evaluation.

Authors:  Young-Seok Park; Sungtae Kim; Seung-Hee Oh; Hee-Jung Park; Sophia Lee; Tae-Il Kim; Young-Kyu Lee; Min-Suk Heo
Journal:  Imaging Sci Dent       Date:  2014-06-11

9.  Ontogenetic changes to bone microstructure in an archaeologically derived sample of human ribs.

Authors:  Amy C Beresheim; Susan Pfeiffer; Marc Grynpas
Journal:  J Anat       Date:  2019-11-15       Impact factor: 2.610

10.  Trabecular architecture of the manual elements reflects locomotor patterns in primates.

Authors:  Stacey A Matarazzo
Journal:  PLoS One       Date:  2015-03-20       Impact factor: 3.240

View more