Literature DB >> 11952737

The effects of fixed and removable implant-stabilised prostheses on posterior mandibular residual ridge resorption.

Paul S Wright1, Per-Olof Glantz, Kjell Randow, Roger M Watson.   

Abstract

This study investigated the change over time in the area of the posterior mandibular residual ridge in patients wearing either i) mandibular overdentures stabilised by two implants (Brånemark System; Nobel Biocare, Göteborg, Sweden) connected by a bar, or ii) mandibular fixed cantilever prostheses stabilised on five or six implants. Proportional measurements were made in order to compare the area of the residual ridge with an area of bone uninfluenced by resorption. Measurements were made by digitising tracings of panoramic radiographs that were taken shortly after implant insertion and up to seven years later. With the use of overdentures, the posterior bone area index reduced by a mean of 1.1% per annum, while a mean bone area index increase of 1.6% per annum was demonstrated in association with fixed prostheses. A multiple linear regression model was fitted to predict the change in posterior area from type of prosthesis, gender, age, years of edentulism and initial height of the mandible. The model was only significant for initial height of mandible (P = 0.04) and type of prosthesis (P = 0.0001). In conclusion, patients rehabilitated with implant-stabilised mandibular overdentures demonstrated low rates of posterior mandibular residual ridge resorption, while patients rehabilitated with implant-stabilised mandibular fixed cantilever prostheses demonstrated bone apposition in the same area.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11952737     DOI: 10.1034/j.1600-0501.2002.130207.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  8 in total

1.  Circumferential bone level and bone remodeling in the posterior mandible of edentulous mandibular overdenture wearers: influence of mandibular bone atrophy in a 3-year cohort study.

Authors:  Alessandra Julie Schuster; Anna Paula da Rosa Possebon; André Ribeiro Schinestsck; Otacílio Luiz Chagas-Júnior; Fernanda Faot
Journal:  Clin Oral Investig       Date:  2021-12-02       Impact factor: 3.573

2.  Comparison of ridge resorption and patient satisfaction in single implant-supported mandibular overdentures with conventional complete dentures: A randomised pilot study.

Authors:  Subin Km; Dheeraj Kumar Koli; Veena Jain; Gunjan Pruthi; Aditi Nanda
Journal:  J Oral Biol Craniofac Res       Date:  2020-11-25

3.  Shape Optimization for Additive Manufacturing of Removable Partial Dentures--A New Paradigm for Prosthetic CAD/CAM.

Authors:  Junning Chen; Rohana Ahmad; Hanako Suenaga; Wei Li; Keiichi Sasaki; Michael Swain; Qing Li
Journal:  PLoS One       Date:  2015-07-10       Impact factor: 3.240

4.  Effect of the number of implants on stress distribution of anterior implant-supported fixed prostheses combined with a removable partial denture: a finite element analysis.

Authors:  Minoo Mahshid; Allahyar Geramy; Massoud Ejlali; Majid Sedaghat Monfared; Shirin Rezvani Habib Abadi
Journal:  J Dent (Tehran)       Date:  2014-05-31

Review 5.  To what extent residual alveolar ridge can be preserved by implant? A systematic review.

Authors:  Ahmed Khalifa Khalifa; Masahiro Wada; Kazunori Ikebe; Yoshinobu Maeda
Journal:  Int J Implant Dent       Date:  2016-11-23

6.  Bone Height Changes of the Mandibular Edentulous Ridge in Screw Retained Versus Telescopic Restorations for Completely Edentulous Patients.

Authors:  Eman Helal; Mohamed El-Zawahry; Ayman Gouda; Amr Hosny Elkhadem; Samira Ibrahim Ibrahim
Journal:  Open Access Maced J Med Sci       Date:  2017-01-18

Review 7.  Biomechanics of oral mucosa.

Authors:  Junning Chen; Rohana Ahmad; Wei Li; Michael Swain; Qing Li
Journal:  J R Soc Interface       Date:  2015-08-06       Impact factor: 4.118

Review 8.  Implant and root supported overdentures - a literature review and some data on bone loss in edentulous jaws.

Authors:  Gunnar E Carlsson
Journal:  J Adv Prosthodont       Date:  2014-08-14       Impact factor: 1.904

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.