Literature DB >> 11952394

Non-invasive tear break-up time in normal Malays.

Norhani Mohidin1, Tan Choon Bay, Maurice Yap.   

Abstract

BACKGROUND: Tear stability in normal Malays with consideration of gender and age has not been reported. In this study, we measured tear stability in normal Malays using the non-invasive tear break-up time (NIBUT).
METHODS: Forty-eight Malay subjects aged seven to 60 years were recruited from among the staff, their children and students of the faculty. NIBUT was measured by noting the time taken for distortions to appear in a reflected image of a grid pattern formed on the corneal surface.
RESULTS: The mean NIBUT of the sample was 15.8 +/- 9.4 (SD) seconds. The median was 14.6 seconds with range of 4.2 seconds to 48.6 seconds. The majority (73 per cent) of subjects had NIBUT values between six and 20 seconds. There was no significant difference in NIBUT values between males and females but there was a decrease of NIBUT with age.
CONCLUSION: The NIBUT values found in this study are comparable to those reported for Asian populations but much less than those of Western populations. Our findings point to the need for local clinical studies in contact lens and contact lens-related research as tear physiology of the local population may not be the same as in Western populations.

Entities:  

Mesh:

Year:  2002        PMID: 11952394     DOI: 10.1111/j.1444-0938.2002.tb03070.x

Source DB:  PubMed          Journal:  Clin Exp Optom        ISSN: 0816-4622            Impact factor:   2.742


  11 in total

1.  Changes in human meibum lipid composition with age using nuclear magnetic resonance spectroscopy.

Authors:  Douglas Borchman; Gary N Foulks; Marta C Yappert; Sarah E Milliner
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-01-31       Impact factor: 4.799

2.  Human meibum chain branching variability with age, gender and meibomian gland dysfunction.

Authors:  Douglas Borchman; Aparna Ramasubramanian
Journal:  Ocul Surf       Date:  2018-12-12       Impact factor: 5.033

3.  Analysis of the composition of lipid in human meibum from normal infants, children, adolescents, adults, and adults with meibomian gland dysfunction using ¹H-NMR spectroscopy.

Authors:  Rashmi K Shrestha; Douglas Borchman; Gary N Foulks; Marta C Yappert; Sarah E Milliner
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-09-21       Impact factor: 4.799

4.  Non-invasive Tear Film Assessment in Normal Population: Effect of Age, Sex, and Interparametric Relationship.

Authors:  Swati Singh; Saumya Srivastav; Ashik Mohamed; Sayan Basu
Journal:  Front Med (Lausanne)       Date:  2022-06-01

5.  Wax-tear and meibum protein, wax-β-carotene interactions in vitro using infrared spectroscopy.

Authors:  Samad Faheem; Sung-Hye Kim; Jonathan Nguyen; Shantanu Neravetla; Matthew Ball; Gary N Foulks; Marta C Yappert; Douglas Borchman
Journal:  Exp Eye Res       Date:  2012-04-28       Impact factor: 3.467

6.  The Relationship Between Tear Ferning Patterns and Non-invasive Tear Break-up Time in Normal Asian Population.

Authors:  Chien Yee Ho; Haliza Abdul Mutalib; Ahmad Rohi Ghazali
Journal:  J Optom       Date:  2015-12-01

7.  Human Meibum Age, Lipid-Lipid Interactions and Lipid Saturation in Meibum from Infants.

Authors:  Samiyyah Sledge; Collin Henry; Douglas Borchman; Marta C Yappert; Rahul Bhola; Aparna Ramasubramanian; Ryan Blackburn; Jonathan Austin; Kayla Massey; Shanzeh Sayied; Aliza Williams; Georgi Georgiev; Kenneth N Schikler
Journal:  Int J Mol Sci       Date:  2017-08-28       Impact factor: 5.923

8.  Insights into Tear Film Stability from Babies and Young Adults: A Study of Human Meibum Lipid Conformation and Rheology.

Authors:  Poonam Mudgil; Douglas Borchman; Aparna Ramasubramanian
Journal:  Int J Mol Sci       Date:  2018-11-07       Impact factor: 5.923

9.  Human Meibum Cholesteryl and Wax Ester Variability With Age, Sex, and Meibomian Gland Dysfunction.

Authors:  Douglas Borchman; Aparna Ramasubramanian; Gary N Foulks
Journal:  Invest Ophthalmol Vis Sci       Date:  2019-05-01       Impact factor: 4.799

Review 10.  Tear instability importance, mechanisms, validity and reliability of assessment.

Authors:  Charles W Mcmonnies
Journal:  J Optom       Date:  2018-01-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.